Skip to main content
NetApp Knowledge Base

Diagnostic panic on node using FlexArray

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • FlexArray
  • Brocade Fiber Channel switch

Issue

  • Nodes go out of quorum.
  • Node encounters a diagnosic panic:

PANIC: DIAGNOSTIC PANIC - System encountered a forced panic condition in SK process config_thread on release 9.16.1P6 (C) on Tue Aug 26 08:54:30 UTC 2025C

  • CRC errors are seen on the output of portshow on one fiber channel switch port:

Interrupts:        7004 Link_failure: 70        Frjt:         0
Unknown:           0    Loss_of_sync: 0 Fbsy:         0
Lli:               7004 Loss_of_sig:  589
Proc_rqrd:         10202        Protocol_err: 0
Timed_out:         0    Invalid_word: 376146324
Tx_unavail:        0    Invalid_crc:  340021
Delim_err:         219  Address_err:  0
Lr_in:             1611 Ols_in:       0
Lr_out:            553  Ols_out:      0
Cong_Prim_in:       0
Nos_in:            60   Nos_out:      59

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.