DS2246 Shelf OT warning on PSU sensor
Applies to
- FAS/AFF Systems
- DS2246 disk shelves
Issue
- When checking the storage fault output, we see the following error:
Enclosure Status: non-critical
Channel: 0a
Shelf: 12
Shelf Type: DS2246
Product Serial Number: SHFFG1451000046
Module Type: IOM6
Temperature Sensors:
Element Status Status Bytes Status Descriptions
1: OK 01,00,24,00
2: OK 01,00,27,00
3: OK 01,00,2E,00
4: OK 01,00,47,00
5: OK 01,00,30,00
6: NONCRITICAL 03,00,58,04 OT WARNING
7: OK 01,00,2C,00
8: OK 01,00,2E,00
- The following alerts are seen in the event logs:
Time Node Severity Event
------------------- ---------------- ------------- ---------------------------
3/14/2024 15:48:25 Node-01 ERROR monitor.shelf.warning: Fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
3/14/2024 15:48:34 Node-01 ALERT ses.status.temperatureWarning: DS2246 (S/N SHFFG1XXX000000) shelf 12 on channel 0c temperature warning for Temperature sensor 6: non-critical status; overtemperature warning. Current temperature: 66 C (150 F). This module is on the rear of the shelf on the lower right power supply.
3/14/2024 15:48:35 Node-01 EMERGENCY monitor.globalStatus.critical: Disk shelf fault