DISK REDUNDANCY FAILED - AutoSupport Message
Applies to
- HA Group Notification (DISK REDUNDANCY FAILED) ERROR
- ONTAP 9
- callhome.dsk.redun.fault
Event Summary
This message occurs when redundant access to the disk storage is lost.
Validate
- EMS reports "
DISK REDUNDANCY FAILED
"::> event log show -severity * -message-name callhome*
Mon Oct 17 19:16:56 +0800 [Nodename: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
Mon Oct 17 19:16:56 +0800 [Nodename: dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration.
- EMS reports "
SinglePathToDiskShelf_Alert
"
Tue Oct 11 23:31:23 +0800 [Nodename: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: SinglePathToDiskShelf_Alert[159491309057xxxxxxxx].
- Note all channels with single path connectivity. Additionally, check for failures using these commands:
::> system health node-connectivity shelf show
::> system health system-connectivity shelf show
- SYSTEM-HEALTH-ALERT.XML reports the following alert:
Controller Nodename has only a single-path configuration to disk shelf 18.10. This might occur when the controller does not have dual-path configuration to stack 18, a SAS HBA port on the controller connected to the disk shelf is disabled, or shelf-to-shelf cabling is incorrect.
Resolution
- Reseat the affected SAS port cable.
- If the issue persists, replace the affected SAS cable.
- If the issue hasn't changed Reseat the SAS HBA
- If the issue persists, replace the affected SAS HBA
- Confirm that redundancy has been restored by running:
::> storage disk show -fields disk,primary-port,secondary-name,secondary-port,shelf,bay
- Additionally, check for failures using these commands:
::> system health node-connectivity shelf show
::> system health system-connectivity shelf show
If you need assistance, contact NetApp technical support.
Additional Information