CriticalFruMultiFaultAlert health alert and cleared following a BMC auto reset
This knowledge base was generated through a script and may contain formatting issues. For the accurate content, please refer to the WIP editor. WIP editor.
Applies to
- AFF A900
- ONTAP 9
- BMC 16.5
Issue
- EMS reports
[node1: env_mgr: monitor.chassisFan.degraded:alert]: Chassis fan is degraded: FanA1 Voltage is unreadable
[node1: env_mgr: monitor.chassisFan.degraded:alert]: Chassis fan is degraded: FanA1 Current is unreadable
[node1: env_mgr: monitor.chassisFan.degraded:alert]: Chassis fan is degraded: FanA2 Voltage is unreadable
[node1: env_mgr: monitor.chassisFan.degraded:alert]: Chassis fan is degraded: FanA2 Current is unreadable
[node1: env_mgr: monitor.chassisFan.degraded:alert]: Chassis fan is degraded: FanA3 Voltage is unreadable
[node1: env_mgr: monitor.chassisFan.degraded:alert]: Chassis fan is degraded: FanA3 Current is unreadable
[node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 AC In Volt is Unreadable
[node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 AC In Curr is Unreadable
[node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 12V Out Volt is Unreadable
[node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 12V Out Curr is Unreadable
[node1: power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU1.
[node1: power_low_monitor: callhome.chassis.power:error]: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1
[node2: cphmd: hm.alert.raised:alert]: Alert Id = CriticalFruMultiFaultAlert , Alerting Resource = 032350002909 raised by monitor chassis
[node2: cphmd: hm.alert.raised:alert]: Alert Id = CriticalFruMultiFaultAlert , Alerting Resource = 032350002956 raised by monitor chassis
[node2: cphmd: hm.alert.raised:alert]: Alert Id = CriticalFruMultiFaultAlert , Alerting Resource = 032350003046 raised by monitor chassis
- After few minutes, issue is resolved
[node2: cphmd: hm.alert.cleared:notice]: Alert Id = CriticalFruMultiFaultAlert , Alerting Resource = 032350002909 cleared by monitor chassis
[node2: cphmd: hm.alert.cleared:notice]: Alert Id = CriticalFruMultiFaultAlert , Alerting Resource = 032350002956 cleared by monitor chassis
[node2: cphmd: hm.alert.cleared:notice]: Alert Id = CriticalFruMultiFaultAlert , Alerting Resource = 032350003046 cleared by monitor chassis