Skip to main content
NetApp Knowledge Base

Correctable memory errors reporting in ONTAP versions with dynamic thresholds

Views:
4,383
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

ONTAP versions:

  • 9.5 and later major releases
  • 9.4P6 and later P releases
  • 9.3P11 and later P releases
  • 9.1P18 and later P releases

Platforms:

  • AFF systems
  • ASA systems
  • FAS systems
  • CriticalCECCCountMemErrAlert

Note: For all other ONTAP versions see How to troubleshoot correctable memory errors on FAS and AFF systems

Issue

  • Health Alert AutoSupport message:

HA Group Notification (Health Monitor process nphm: CriticalCECCCountMemErrAlert[DIMM-16]) ALERT

  • EMS reports:

[mgwd: callhome.hm.alert.critical:alert]: Call home for Health Monitor process nphm: CriticalCECCCountMemErrAlert[DIMM-16].

  • Management Log

[nphmd: hm.alert.raised:alert]: Alert Id = CriticalCECCCountMemErrAlert , Alerting Resource = DIMM-16 raised by monitor controller

  • Health Monitor reports

::> system health alert show
               Node: Node1
           Alert ID: CriticalCECCCountMemErrAlert
           Resource: DIMM-1
           Severity: Critical
    Indication Time: Wed Jan 10 16:45:18 2024
           Suppress: false
        Acknowledge: false
     Probable Cause: The DIMM has degraded, leading to memory errors.
  Possible Effect: Memory issues can lead to a catastrophic system panic,
                     which can lead to data downtime on the node.
 Corrective Actions:
 1. Contact technical support to obtain a new DIMM of the same specification.
 2. If possible, perform a takeover of this node and bring the node down for maintenance.
 3. Refer to the DIMM replacement guide for your given hardware platform to replace the DIMM.
 4. Bring the storage system online.

Alertdditional Information   
 Slot Name: DIMM-16
 CPU Socket: 0
 Channel: 0
 Slot Number on a Channel: 0
 Correctable ECC Error Count: 329793
 Uncorrectable ECC Error Count: 0
 Correctable ECC Error Limit: 0
 CECC Alert Method: bucket
 Correctable ECC Replace DIMM: true
 Failure Reason: none
 Correctable ECC Error Minimum Count: 325104
 Correctable ECC Error Bucket Count: 177243
 Correctable ECC Replace DIMM Count: 3
 DIMM Serial Number: *****
 Node Serial Number: *****
 Node Model: FAS****
 Alerting Resource Name    DIMM-16

  • Memory dimm show reports the dimm status as degraded

Cluster::> memory dimm show
              DIMM     UECC  CECC  Alert    CPU           Slot          Failure
Node          Name    Count Count Method Socket Channel Number Status    Reason
------------- ------- ----- ----- ------ ------ ------- ------ ------- --------
Cluster-01
              DIMM-1      0     0 bucket      1       0      0 ok          none
              DIMM-2      0     0 bucket      1       0      1 ok          none
              DIMM-3      0     0 bucket      1       1      0 ok          none
              DIMM-4      0     0 bucket      1       1      1 ok          none
              DIMM-5      0     0 bucket      1       3      1 ok          none
              DIMM-6      0     0 bucket      1       3      0 ok          none
              DIMM-7      0     0 bucket      1       2      1 ok          none
              DIMM-8      0     0 bucket      1       2      0 ok          none
              DIMM-9      0     0 bucket      0       2      0 ok          none
              DIMM-10     0     0 bucket      0       2      1 ok          none
              DIMM-11     0     0 bucket      0       3      0 ok          none
              DIMM-12     0     0 bucket      0       3      1 ok          none
              DIMM-13     0     0 bucket      0       1      1 ok          none
              DIMM-14     0     0 bucket      0       1      0 ok          none
              DIMM-15     0     0 bucket      0       0      1 ok          none
              DIMM-16     0     0 bucket      0       0      0 degraded    none

 

  • Performance issues may be seen when errors are seen in sktrace in AutoSupport logs
CECC_LOG_ENTRY:  Number of correctable ECC since boot 355314194: Information about Correctable ECC: ECC error at DIMM 8: CE-12-1234-12345678,ADDR 0xaada0eec0,
(Node(0), Memory controller(1), CH(2), DIMM(0), Rank(0), Bank Group(3), Bank(0x2), Row(0x2174), Col(0x1d8))

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.