Controller temperature sensor MemoryX_Hot is reporting Asserted
Applies to
- ONTAP 9
- AFF Systems
- FAS Systems
Issue
- Controller fault LED is on
- Sensor from the
SP-LATEST-IPMIlogs report as AssertedMemory_HotMemory0_Hot-
Memory1_Hot
======================================/usr/local/bin/ipmi sensors===============================Sensor Name | Current | Unit | Status | LCR | LNC | UNC | UCR-----------------+------------+------------+------------+-----------+-----------+-----------+-----------Memory0_Hot | 0x0 | discrete | Deasserted | na | na | na | naCPU1_Error | 0x0 | discrete | Deasserted | na | na | na | naCPU1_Therm_Trip | 0x0 | discrete | Deasserted | na | na | na | naCPU1_Hot | 0x0 | discrete | Deasserted | na | na | na | naMemory1_Hot | 0x0 | discrete | Asserted | na | na | na | naPCH_Hot | 0x0 | discrete | Deasserted | na | na | na | na- System environment sensors show command reports
::> system environment sensors show -state !normal
Node Sensor State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
node1
Memory1 Hot fault HOT
- SP-reboot does not clear this sensor status