Controller temperature sensor MemoryX_Hot is reporting Asserted
Applies to
- ONTAP 9
- AFF Systems
- FAS Systems
Issue
- Controller fault LED is on
- Sensor from the
SP-LATEST-IPMI
logs report as AssertedMemory_Hot
Memory0_Hot
-
Memory1_Hot
======================================
/usr/local/bin/ipmi sensors
===============================
Sensor Name | Current | Unit | Status | LCR | LNC | UNC | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
Memory0_Hot | 0x0 | discrete | Deasserted | na | na | na | na
CPU1_Error | 0x0 | discrete | Deasserted | na | na | na | na
CPU1_Therm_Trip | 0x0 | discrete | Deasserted | na | na | na | na
CPU1_Hot | 0x0 | discrete | Deasserted | na | na | na | na
Memory1_Hot | 0x0 | discrete | Asserted | na | na | na | na
PCH_Hot | 0x0 | discrete | Deasserted | na | na | na | na
- System environment sensors show command reports
::> system environment sensors show -state !normal
Node Sensor State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
node1
Memory1 Hot fault HOT
- SP-reboot does not clear this sensor status