Search
- Filter results by:
- View attachments
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Controller_temperature_sensor_Memory1_Hot_is_assertedSensor from the SP-LATEST-IPMI logs report as Asserted Sensor Name | Current | Unit | Status | LCR | LNC | UNC | UCR Memory0_Hot | 0x0 | discrete | Deasserted | na | na | na | na CPU1_Error | 0x0 | di...Sensor from the SP-LATEST-IPMI logs report as Asserted Sensor Name | Current | Unit | Status | LCR | LNC | UNC | UCR Memory0_Hot | 0x0 | discrete | Deasserted | na | na | na | na CPU1_Error | 0x0 | discrete | Deasserted | na | na | na | na CPU1_Therm_Trip | 0x0 | discrete | Deasserted | na | na | na | na CPU1_Hot | 0x0 | discrete | Deasserted | na | na | na | na Memory1_Hot | 0x0 | discrete | Asserted | na | na | na | na PCH_Hot | 0x0 | discrete | Deasserted | na | na | na | na
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/NS224_sensors_periodically_go_unavailable_then_recoverWed Oct 12 23:26:02 -0700 [Node-05: dsa_worker5: ses.status.ACPWarn:error]: NS224NSM100 (S/N SHFGB2118000055) shelf 10 on channel 0x ACP Processor warning for shelf ACP processor 1: communication erro...Wed Oct 12 23:26:02 -0700 [Node-05: dsa_worker5: ses.status.ACPWarn:error]: NS224NSM100 (S/N SHFGB2118000055) shelf 10 on channel 0x ACP Processor warning for shelf ACP processor 1: communication error. ; Alternate Control Path hardware failed . Wed Oct 12 23:26:02 -0700 [Node-05: dsa_worker5: ses.status.battery.error:error]: NS224NSM100 (S/N SHFGB2118000055) shelf 10 on channel 0x battery failure error for Coin Battery 1: not installed or hardware failure.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Disks_missing_through_IOM12E_and_PSU_FAN_and_temperature_errorsThu Apr 08 06:12:57 +0000 [node_name: dsa_worker2: ses.status.procCplxError:alert]: DS224-12 (S/N SHFNC0123456789) shelf 0 on channel 0b Processor Complex error for Processor Complex 1: PCM on partner...Thu Apr 08 06:12:57 +0000 [node_name: dsa_worker2: ses.status.procCplxError:alert]: DS224-12 (S/N SHFNC0123456789) shelf 0 on channel 0b Processor Complex error for Processor Complex 1: PCM on partner not installed This module is on the unknown location. This module is on the rear of the shelf at the top left, on shelf module A. This module is on the rear of the shelf at the top right, on shelf module B.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/NSM100_modules_fail_to_read_I2C_EEPROMFans: Element Status Status Bytes Status Descriptions 1: NOT AVAILABLE 07,00,00,70 OFF, FAIL 2: NOT AVAILABLE 07,00,00,70 OFF, FAIL 3: NOT AVAILABLE 07,00,00,70 OFF, FAIL 4: NOT AVAILABLE 07,00,00,70 ...Fans: Element Status Status Bytes Status Descriptions 1: NOT AVAILABLE 07,00,00,70 OFF, FAIL 2: NOT AVAILABLE 07,00,00,70 OFF, FAIL 3: NOT AVAILABLE 07,00,00,70 OFF, FAIL 4: NOT AVAILABLE 07,00,00,70 OFF, FAIL 5: NOT AVAILABLE 07,00,00,70 OFF, FAIL 6: NOT AVAILABLE 07,00,00,70 OFF, FAIL 7: NOT AVAILABLE 07,00,00,70 OFF, FAIL 8: NOT AVAILABLE 07,00,00,70 OFF, FAIL 9: NOT AVAILABLE 07,00,00,70 OFF, FAIL 10: NOT AVAILABLE 07,00,00,70 OFF, FAIL 11: NOT AVAILABLE 07,00,00,70 OFF, FAIL 12: NOT AVAILA…
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/SF4805_reports_error_checking_sensor_for_xxxxApplies to SF4805 Issue SF4805 reports Error checking sensor for xxxx. Example: Error checking sensor for FANxx Error checking sensor for PSx Error checking sensor for Inlet Temp Error checking sensor...Applies to SF4805 Issue SF4805 reports Error checking sensor for xxxx. Example: Error checking sensor for FANxx Error checking sensor for PSx Error checking sensor for Inlet Temp Error checking sensor for Exhaust Temp