Controller Hardware Upgrade: Aggregate Relocation Fails on 'vetoed by lock_manager'
Applies to
- Ontap 9
- Controller Hardware Upgrade
- Common Internet File System (CIFS) active sessions
Issue
- Hardware upgrade from FAS2620 to FAS2820 using
system controller replace
Paused-on-error
due to veto bylock_manager
::*> controller replace show-details
(system controller replace show)
Node Status Error-Action
-------- ---------------- ------------------------------------
node-01 Paused-on-error Failed to relocate aggrs. Reason: One or more aggregates failed to relocate on node node-01.
Failed: Operation was vetoed by lock_manager. Check the event log..
Check the status of aggregates and disks using "storage aggregate relocation show" command.
Correct the issues, and then resume the operation.
node-02 None
2 entries were displayed.