Cluster switch log collection fails for BES switch
Applies to
- NetApp ONTAP 9
- Cluster Network Switches - BES-53248
Issue
- Cluster switch log collection for one switch fails with the following error:
cluster::*> system cluster-switch log show
Periodic Periodic Support
Switch Log Enabled Log State Log State
----------------------------------------- ----------- ----------- -----------
sw1 true failed failed
cluster::*> system cluster-switchlog show-instanceSwitchName: sw1PeriodicLogEnabled: truePeriodicLogStatus: Failure in setup process: switch password errorSupportLogRequested: falseSupportLogStatus: Failure in setup process: switch password error- Relevant switch logs:
Aug 24 01:04:34 sw1-1 SSHD[tRpcsrv.02002]: scp.c(2272)38320 %% NOTE SCP remote file transfer operation is unsuccessful.Aug 24 01:04:34 sw1-1 CLI_WEB[tRpcsrv.02002]: transfer.c(7884)38319 %% INFO Unable to inform transfer module about SCP remote transfer complete operation.Aug 24 01:04:34 sw1-1 SSHD[tRpcsrv.02002]: scp.c(2168)38318 %% NOTE SCP file (id_rsa.pub) download started by user (mon_ontap_user) from remote host (10.238.62.230) to file (/mnt/fastpath/id_rsa_log_collect_ev00nas01cs_mon_ontap_user.pub)