Cluster interconnect link down in a two-node switchless cluster
Applies to
- FAS systems
- AFF systems
- Two-node switchless cluster
Issue
- The cluster ports are connected to each other in a two-node switchless cluster, as shown in the below example:
- Node-1 e0a <-> Node-2 e0a
- Node-1 e0b <-> Node-2 e0b
- In this scenario, if one of the cluster ports goes down on one node, then that cluster interconnect link goes down on both the nodes at the same time.
For Example:
Tue Jul 27 02:24:18 IST [Node-1: kernel: netif.linkDown:info]: Ethernet e0a: Link down, check cable.
Tue Jul 27 02:24:21 IST [Node-1: vifmgr: vifmgr.portdown:notice]: A link down event was received on node Node-1, port e0a.
Tue Jul 27 02:24:24 IST [Node-1: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e0a on node Node-1 has gone down unexpectedly
Tue Jul 27 02:24:18 IST [Node-2: kernel: netif.linkDown:info]: Ethernet e0a: Link down, check cable.
Tue Jul 27 02:24:21 IST [Node-2: vifmgr: vifmgr.portdown:notice]: A link down event was received on node Node-2, port e0a.
Tue Jul 27 02:24:25 IST [Node-2: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e0a on node Node-2 has gone down unexpectedly.
- The cluster LIFs hosted on the down cluster ports will be moved to the redundant cluster ports on both nodes.
For Example:
Tue Jul 27 02:24:24 IST [Node-1: vifmgr: vifmgr.lifsuccessfullymoved:notice]: LIF Node-1_clus1 (on virtual server 5432198765), IP address 169.X.X.X, is now hosted on node Node-1, port e0b.
Tue Jul 27 02:24:25 IST [Node-2: vifmgr: vifmgr.lifsuccessfullymoved:notice]: LIF Node-2_clus1 (on virtual server 5432198765), IP address 169.X.X.X, is now hosted on node Node-2, port e0b.