"Chassis Power Fault detected" messages in ConfigAdvisor
Applies to
- FAS8300 / FAS8700 / AFF A400
- 1600W PSU
- All ONTAP versions
- BMC firmware 13.6 or lower
- ActiveIQ ConfigAdvisor
Issue
- ActiveIQ ConfigAdvisor reports an alert of
Chassis Power Fault detected
with further details ofChassis power supply 2 and 1 have failed
, been removed, or turned-off
- System is up and running and no PSU failure is noticed upon physical inspection
system node environment sensors show -name PSU*
will only display sensorsPSU1 Vin Type
andPSU2 Vin Type
as failed
cluster::> system node environment sensors show -name PSU*
Node Sensor State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
node01
PSU1 VIN failed
PSU1 VOUT normal
12012 mV 11336 11440 12948 13156
PSU1 Curr IIN normal
832 mA 0 - 9984 12012
PSU1 IOUT normal
12000 mA 0 - 130000 132000
PSU1 PIN normal
170400 mW 7100 14200 1611700 1796300
PSU1 POUT normal
149100 mW 7100 14200 1611700 1796300
PSU1 Inlet normal
22 C 0 - 58 63
PSU1 Hot normal
32 C 0 - 100 105
PSU1 FB Hot normal
29 C 0 - 100 105
PSU1 FAN normal
4500 RPM 800 1200 - -
PSU2 VIN failed
PSU2 VOUT normal
12012 mV 11336 11440 12948 13156
PSU2 Curr IIN normal
988 mA 0 - 9984 12012
PSU2 IOUT normal
15000 mA 0 - 130000 132000
PSU2 PIN normal
198800 mW 7100 14200 1611700 1796300
PSU2 POUT normal
177500 mW 7100 14200 1611700 1796300
PSU2 Inlet normal
24 C 0 - 58 63
PSU2 Hot normal
33 C 0 - 100 105
PSU2 FB Hot normal
30 C 0 - 100 105
PSU2 FAN normal
4500 RPM 800 1200 - -
PSU1 Present normal
PRESENT
PSU2 Present normal
PRESENT
PSU1 normal
GOOD
PSU2 normal
GOOD