Call home for SHELF COOLING UNIT FAILED
Applies to
DS224-12 shelves
Issue
The system generated an AutoSupport (ASUP) alert with the error SHELF COOLING UNIT FAILED
EMS
[node-01:dsa_worker1:ses.status.fanWarning:notice]: DS224-12 (S/N xxxxxxxxxxxx) shelf 24 on channel 0b cooling fan warning for Cooling element 1: not installed. This module is on the rear of the shelf on the lower left power supply.
[node-01:dsa_worker1:callhome.shlf.fan.warn:error]: Callhome for SHELF COOLING UNIT FAILED
[node-01:dsa_worker1:ses.status.fanWarning:notice]: DS224-12 (S/N xxxxxxxxxxxx) shelf 24 on channel 0b cooling fan warning for Cooling element 2: not installed.
[node-01:dsa_worker1:ses.status.temperatureWarning:alert]: DS224-12 (S/N xxxxxxxxxxxx) shelf 24 on channel 0b temperature warning for Temperature sensor 6: not installed.
[node-01:dsa_worker1:ses.status.temperatureWarning:alert]: DS224-12 (S/N xxxxxxxxxxxx) shelf 24 on channel 0b temperature warning for Temperature sensor 7: not installed.
Additional sysconfig output indicated:
ENVIRONMENT
Cooling Units by element:
[1] Unavailable
[2] Unavailable
Shelf temperatures by element:
[6] Unavailable
[7] Unavailable
Temperature thresholds by element:
[6] High critical: Unavailable; high warning: Unavailable
Low critical: Unavailable; low warning: Unavailable
[7] High critical: Unavailable; high warning: Unavailable
Low critical: Unavailable; low warning: Unavailable