Call home for CHASSIS FAN FRU FAILED in AFF A250 or AFF C250
Applies to
- AFF A250, AFF C250
- ASA A250, ASA C250
- FAS500f
- BMC fw. 15.10+
- ONTAP 9
Issue
- The following errors are reported in event logs:
[Node-02: env_mgr: monitor.chassisFan.stop:debug]: Chassis fan contains at least one stopped fan: Fan1 (0 RPM)
[Node-02: env_mgr: callhome.c.fan.fru.fault:debug]: Call home for CHASSIS FAN FRU FAILED: Fan1
Or
[Node-04: env_mgr: monitor.chassisFan.stop:debug]: Chassis fan contains at least one stopped fan: Sysfan4_F2_Speed (failed)
[Node-04: env_mgr: callhome.c.fan.fru.fault:debug]: Call home for CHASSIS FAN FRU FAILED: Sysfan4_F2_Speed
- The sensor status for one or both fans is
"BAD"in the SP sensors section:
Fan2 State discrete normal normal GOOD
Fan1 State discrete fault normal BAD
And
Sensor name | reading | unit | status| lnr | lcr | lnc | unc | ucr | unr
Sysfan4_F1_Speed | 9204.000 | RPM | ok | 0.000 | 936.000 | 2964.000 | 33072.000 | 34008.000 | 34944.000
Sysfan4_F2_Speed | 0.000 | RPM | nr | 0.000 | 936.000 | 2964.000 | 33072.000 | 34008.000 | 34944.000
- The error remains in the same slot, after swapping the FAN positions with known working units.