Both shelf modules report CRITICAL condition on DS2246
Applies to
DS2246
Issue
- Shelf reports critical condition
::> run local storage show fault
Enclosure Status: critical
Channel: 0a
Shelf: 1
Shelf Type: DS2246
Product Serial Number: xxxxxxxxx
Module Type: IOM6
- Frequent alerts generated from both controllers
HA Group Notification (SHELF_FAULT) WARNING
- Both IOM modules with critical status however they continue to operate as normal
Vendor Unique Element 83-IOM6: (SAS)
Element Status Status Bytes Status Descriptions
1 [IOM6 A] : CRITICAL 02,08,00,A4 MASTER, RESERVED, RESERVED, RESERVED
2 [IOM6 B] : CRITICAL 02,00,00,A4 RESERVED, RESERVED, RESERVED
- All disks might show
Disk Elements:
Element Status Status Bytes Status Descriptions
0 [Bay 0]: NONCRITICAL 03,00,00,10 DEVICE OFF
1 [Bay 1]: NONCRITICAL 03,01,00,10 DEVICE OFF
2 [Bay 2]: NONCRITICAL 03,02,00,10 DEVICE OFF
...
23 [Bay 23]: NONCRITICAL 03,17,00,10 DEVICE OFF
- Shelf sensors might show
Temperature Sensors:
Element Status Status Bytes Status Descriptions
1: NONCRITICAL 03,00,14,01 UT WARNING
2: CRITICAL 02,00,14,03 UT WARNING, UT FAILURE
- Reseating both IOM modules one at a time (with remove for at least 70 seconds before reinserting) didn't resolved the issue