Search
- Filter results by:
- View attachments
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/sysconfig_a_reports_Shelf_Serial_Number_instead_of_Shelf_ID_after_IOM_reseat_replacementsysconfig -a displays shelf serial number instead of the shelf ID in front the disks: sasadmin expander_map might display an invalid/alternate shelf ID : Level 10: WWN 50050cc104fd6d3f, ID 150, Serial...sysconfig -a displays shelf serial number instead of the shelf ID in front the disks: sasadmin expander_map might display an invalid/alternate shelf ID : Level 10: WWN 50050cc104fd6d3f, ID 150, Serial Number ' SHM09797XXXXX', Product 'DS424IOM3 ', Rev '0172', Slot B You might receive a duplicate shelf ID error in the messages log: [sas.shelf.conflict:error]: At least two SAS disk shelves have the same disk shelf ID.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/How_to_map_DS2246_elements_used_by_error_messages_and_SES_codes_to_a_physical_location_on_the_shelfApplies to DS2246 Description This article explains how to map DS2246 elements to a physical location on the shelf.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/CONFIGURATION_ERROR_reported_due_to_power_supply_faultConfiguration issue is reported on the disk shelves due to power supply fault as shown below: Sat Mar 06 02:33:15 GMT [Nodename: ses_admin: ses.psu.powerReqError:critical]: Not enough power supplies a...Configuration issue is reported on the disk shelves due to power supply fault as shown below: Sat Mar 06 02:33:15 GMT [Nodename: ses_admin: ses.psu.powerReqError:critical]: Not enough power supplies are present in channel ## disk shelf 37 to satisfy disk drive and shelf power requirements. Sat Mar 06 02:33:00 GMT [Nodename: monitor: monitor.globalStatus.critical:critical]: Power Supply Status Critical.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/OPS_panel_display_panel_fails_on_DS2246_and_FAS2240OPS panel/display panel fails on DS2246 and FAS2240 replace ops panel
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/In-Band_ACP_Setup_and_SupportThis article outlines how to migrate from OOB to In-Band ACP support - the default in ONTAP 9.0 and later. There must be dual path to each IOM to support In-Band ACP Starting with AFF A700, AFF A300, ...This article outlines how to migrate from OOB to In-Band ACP support - the default in ONTAP 9.0 and later. There must be dual path to each IOM to support In-Band ACP Starting with AFF A700, AFF A300, AFF A200 and FAS9000, FAS8200, and FAS2600 series storage systems, OOB ACP is not supported. Replace IOM3 modules with IOM6 modules, and/or use IOM12 modules to provide In-Band ACP support for all storage (recommended by NetApp). Migrate to In-Band ACP, but without any ACP support for IOM3 modules.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Both_shelf_modules_report_CRITICAL_condition_on_DS2246Shelf reports critical condition Enclosure Status: critical Both IOM modules with critical status however they continue to operate as normal 1 [IOM6 A] : CRITICAL 02,08,00,A4 MASTER, RESERVED, RESERVE...Shelf reports critical condition Enclosure Status: critical Both IOM modules with critical status however they continue to operate as normal 1 [IOM6 A] : CRITICAL 02,08,00,A4 MASTER, RESERVED, RESERVED, RESERVED 2 [IOM6 B] : CRITICAL 02,00,00,A4 RESERVED, RESERVED, RESERVED Element Status Status Bytes Status Descriptions 2: CRITICAL 02,00,14,03 UT WARNING, UT FAILURE Reseating both IOM modules one at a time (with remove for at least 70 seconds before reinserting) didn't resolved the issue
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/SAS_Host_Adapter_with_rate_unknown_for_one_PHY_remote_shelfSAS cable X66016A-R6 SAS cable X66021A-R6 SAS cable X66047 SAS cable X66030A One SAS channel (PHY) has unknown status for remote shelf stack. slot 0: SAS Host Adapter 0b (PMC-Sierra PM8001 rev. C, SAS...SAS cable X66016A-R6 SAS cable X66021A-R6 SAS cable X66047 SAS cable X66030A One SAS channel (PHY) has unknown status for remote shelf stack. slot 0: SAS Host Adapter 0b (PMC-Sierra PM8001 rev. C, SAS, <UP>) Firmware rev: 01.12.09.00 Base WWN: xxxxxxxxxxxxxxx Phy State: [4] Enabled, 6.0 Gb/s [5] Enabled, 6.0 Gb/s [6] Enabled, Rate unknown [7] Enabled, 6.0 Gb/s QSFP Vendor: Molex Inc. QSFP Part Number: 112-00274+A0 QSFP Type: Optical (1490nm DFB) 5m ID:00 QSFP Serial Number: serial_number
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Disk_shelf_DS2246_is_reporting_UNDER_TEMPERATURE_UT_warning_alertsDisk shelf DS2246 reports UT WARNING alerts and after a while the warning gets auto corrected. [FAS-01: statd: monitor.shelf.warning:warning]: Fault reported on disk storage shelf attached to channel ...Disk shelf DS2246 reports UT WARNING alerts and after a while the warning gets auto corrected. [FAS-01: statd: monitor.shelf.warning:warning]: Fault reported on disk storage shelf attached to channel 0a. [FAS-01: monitor.shelf.fault.ok:info]: Fault previously reported on disk storage shelf attached to channel 0a has been corrected. Though the temperature in the Data Center is normal, the warning is generated daily and goes back to normal state after some time.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/How_to_remove_a_shelf_from_ONTAPApplies to ONTAP 9 Disk shelves DS212C DS224X DS424X DS4486 DS460C Description Before removing a shelf the data needs to be evacuated and ownership and partitioning removed.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/DS2246_Shelf_fans_critical_status_running_at_high_speedShelf: 10 SES device path: local access: 3a.125L103 Module type: IOM6; monitoring is active Shelf status: critical condition SES Configuration, shelf 10: logical identifier=0x500a09800385ace9 vendor i...Shelf: 10 SES device path: local access: 3a.125L103 Module type: IOM6; monitoring is active Shelf status: critical condition SES Configuration, shelf 10: logical identifier=0x500a09800385ace9 vendor identification=NETAPP product identification=DS2246 [truncated...] Cooling Unit installed element list: 1, 2, 3, 4; with error: 1, 2, 3, 4 Cooling Units by element: [1] 8000 RPM [2] 8020 RPM [3] 8000 RPM [4] 8000 RPM
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/IOM_upgrade_requires_a_cold_swapThis article describes the steps required for a cold-swap upgrade. When replacing the IOM module in a shelf with a different model it requires the following components to be powered off during the cha...This article describes the steps required for a cold-swap upgrade. When replacing the IOM module in a shelf with a different model it requires the following components to be powered off during the change: ALL nodes that connect to the impacted shelves. ALL ATTO bridges (if applicable) that connect to the impacted shelves. The shelves of which the IOM model will be changed. IOM3 to IOM6 IOM3 to IOM12* IOM6 to IOM12* *Be aware of SAS port differences between IOM3/IOM6 (QSFP) and IOM12 (MiniSAS-HD)