Both controllers go down when performing PSU test
Applies to
FAS2650
Issue
- Both controllers shutdown when performing a power test on a single PSU on the shelf
- EMS logs show the controllers went down due to '
chassis under temperate environmental shutdown
' after power was removed from PSU
[Node01: monitor: monitor.globalStatus.critical:EMERGENCY]: Power Supply Status Critical: PSU1. Disk shelf fault.
[Node01: env_mgr: monitor.shutdown.chassisUnderTemp:error]: Chassis temperature is too cold: System temperature is critical low. System will be shutdown in 2 minutes
[Node01: env_mgr: callhome.chassis.undertemp:EMERGENCY]: Call home for CHASSIS UNDER TEMPERATURE SHUTDOWN
- Environment log shows PSU sensor 7 decreasing before hitting critical undertemperature
Shelf temperatures by element:
[1] 30 C (86 F) (ambient) Normal temperature range
[2] 33 C (91 F) Normal temperature range
[3] 33 C (91 F) Normal temperature range
[4] 33 C (91 F) Normal temperature range
[5] 33 C (91 F) Normal temperature range
[6] 34 C (93 F) Normal temperature range
[7] 3 C (37 F) Undertemperature failure!
[8] 35 C (95 F) Normal temperature range
[9] 49 C (120 F) Normal temperature range
[10] 42 C (107 F) Normal temperature range
[11] 60 C (140 F) Normal temperature range
[12] 36 C (96 F) Normal temperature range
[13] 43 C (109 F) Normal temperature range
[14] 60 C (140 F) Normal temperature range
[15] 37 C (98 F) Normal temperature range