BMC firmware update causes SSH access failure on NetApp FAS500F
Applies to
- NetApp FAS500F
- ONTAP 9.13.1P4
- Baseboard Management Controller (BMC)
Issue
- After updating the BMC firmware from version 15.11 to 15.13, SSH access to the BMC on
node-01fails (connection times out, no error message). system service-processor image show -instanceindicates the primary image is 15.13, butLastUpdateStatusisfailed.
::> system service-processor image show -instance
Node: node-01 Image: primary Type: BMC Image Status: installed Is Image Current: true Firmware Version: 15.13Firmware Autoupdate: true Last Update Status: failed
Node: node-01 Image: backup Type: BMC Image Status: installed Is Image Current: false Firmware Version: 15.11Firmware Autoupdate: true Last Update Status: failed
- Health alert
SPAutoUpgradeFailedMajorAlertis active.
::*> system health alert show
Node: node-01 Alert ID: SPAutoUpgradeFailedMajorAlert
system service-processor showindicates the status is true and online.
::> system service-processor show
Node Type Status Configured Firmware Version IP Address----------------------------------------------------------------------node-01 BMC online true 15.13 10.23.45.678