About the configuration ports of FAS2700 series 2-node Switchless Cluster

Views:
47
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

Applies to

  • FAS2720
  • FAS2750

Answer

  • There are two types of MBs in the FAS2700 series.(UTA2 and RJ45 types)
  • Cluster Interconnect can use ports other than e0a and e0b.
  • e0c/e0d and e0e/e0f are connected to separate chips.
  • For UTA2, Cluster Interconnect can be configured as e0c and e0d or e0e and e0f.
  • For RJ45, Cluster Interconnect can be configured as e0c and e0e or e0d and e0f.

Additional Information

  • For UTA2, the same chip must be set to the same mode, so the following port configuration is recommended to avoid wasteful connections between chips.
     if e0c is set to cna, e0d on the same chip must also be cna.
    Therefore, for UTA2, Cluster Interconnect is configured as e0c and e0d or e0e and e0f.

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.