Service Processor automatic firmware failed due to network interface issue
Applies to
- ONTAP 9
- FAS/AFF systems
- SP (Service Processor)
- BMC (Baseboard Management Controller)
Issue
- The automatic firmware upgrade failed due to the inability to transfer the SP firmware image using the network interface.
Node03: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update has been successfully scheduled from 4.11 to 4.11P1'}[?]
Node03: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update from 4.11 to 4.11P1 has been triggered.'}[?]
Node03: servprocd: sp.servprocd.upd.unexpt.evts:debug]: params: {'reason': 'Unable to transfer SP firmware image using network interface'}
Node03: servprocd: sp.servprocd.upd.error:error]: SP update error: SP firmware update failure has been detected.[?]
OR
Servprocd::SpUpdate: writeImage: spcs sp update command failed (SSL_CTX_use_PrivateKey_file: key values mismatch exception occurred in spcc_sp_update code)
- The
system health statusshowisdegraded.
::*> system health status showStatus---------------degraded
- The
system health alert showdisplaysSPAutoUpgradeFailedMajorAlert.
::*> system health alert show Node: Node1 Alert ID: SPAutoUpgradeFailedMajorAlert Resource: SP Upgrade Severity: Major Indication Time: Sun Suppress: false Acknowledge: false Probable Cause: A Service Processor automatic firmware update failure was detected, which can result in Service Processor not being updated to the latest available compatible firmware package. Possible Effect: Suboptimal system behavior can result from Service Processor not being updated to the latest available compatible firmware package.Corrective Actions: 1. Use the "system service-processor image show" command to display the firmware version that SP is currently booted from. 2. Manually upgrade Service Processor by using the "system service-processor image update" command. 3. Allow sufficient time for the system to update Service Processor firmware to the specified SP firmware package. 4. Contact the technical support if the alert persists. Node: Node2 Alert ID: SPAutoUpgradeFailedMajorAlert Resource: SP Upgrade Severity: Major Indication Time: Sun Suppress: false Acknowledge: false Probable Cause: A Service Processor automatic firmware update failure was detected, which can result in Service Processor not being updated to the latest available compatible firmware package. Possible Effect: Suboptimal system behavior can result from Service Processor not being updated to the latest available compatible firmware package.Corrective Actions: 1. Use the "system service-processor image show" command to display the firmware version that SP is currently booted from. 2. Manually upgrade Service Processor by using the "system service-processor image update" command. 3. Allow sufficient time for the system to update Service Processor firmware to the specified SP firmware package. 4. Contact the technical support if the alert persists.2 entries were displayed.