AFF-A800 System had amber LED due to BIOS MRC MEMORY WARNING on Memory DIMM
Applies to
AFF-A800
Issue
- The node had a amber LED which was caused due to BIOS MRC MEMORY WARNING on DIMM.
- The DIMM had mapped out on previous boot but the node was booted up which made the amber LED lit.
SP-LATEST-IPMI
====================================== hsamcmd --fault-show-all =============================== tag origin fld fault reason count time ---- ------- ---- ------------- ------ ----- 1 bios /chassis-1/controller-a/dimm-9 BIOS MRC MEMORY WARNING 27 Fri May 10 22:27:05 2024 Fault Lights On: /chassis-1 27 /chassis-1/controller-a 27 /chassis-1/controller-a/dimm-9 27
SP-CONSOLE-LOGS
(Previous boot console Logs)CPU reset. [m[2J[HBIOS Version: 13.14 PEI start. CPU PEI initialization. Wait BMC self-test result. BMC self-test: OK. Running full memory initialization. MEMORY WARNING: Major Code 0x30 Minor Code 0x2D DIMM:9. MEMORY WARNING: Major Code 0x30 Minor Code 0x2D DIMM:9. MEMORY WARNING: Major Code 0x30 Minor Code 0x2D DIMM:9. MEMORY WARNING: Major Code 0x30 Minor Code 0x2D DIMM:9. MEMORY WARNING: Major Code 0x30 Minor Code 0x2D DIMM:9. MEMORY WARNING: Major Code 0x30 Minor Code 0x2D DIMM:9. DIMM: 9 mapped out. BIOS MRC mapped out DIMM. Major Code 0x0A Minor Code 0x03 DIMM: 9 mapped out. BIOS MRC mapped out DIMM. Major Code 0x0B Minor Code 0x1C MEMORY WARNING: Major Code 0x30 Minor Code 0x2D DIMM:9. MEMORY WARNING: Major Code 0x30 Minor Code 0x2D DIMM:9. MEMORY WARNING: Major Code 0x30 Minor Code 0x2D DIMM:9. MEMORY WARNING: Major Code 0x30 Minor Code 0x2D DIMM:9. DIMM: 9 mapped out. BIOS MRC mapped out DIMM. Major Code 0x0A Minor Code 0x03 DIMM: 9 mapped out. BIOS MRC mapped out DIMM. Major Code 0x0B Minor Code 0x1C