e1a or e1b port down
Applies to
- AFF A800
- FAS2820
Issue
- Cluster e1a or HA Interconnect e1b port is down in
::> system node run -node node_name -command sysconfig -aoutput. Example:
slot 1: Dual 40/100G Ethernet T62100-CR
e1a MAC Address: 00:07:43:51:03:00 (auto-unknown-fd-down)
e1b MAC Address: 00:07:43:51:03:08 (auto-unknown-fd-down)
Device Type: T6 2
Firmware Version: 1.24.12.0
Part Number: 110122860B1
Hardware Revision: 0
Serial Number: PT09190900
- The ONTAP event message system (EMS) report. Example:
Mon Apr 14 18:48:11 +0900 [node_name: intr: netif.linkDown:info]: Ethernet e0a: Link down, check cable.
ornetif.linkDown: Ethernet a0b: Link down, check cable.netif.linkDown: Ethernet e1b: Link down, check cable.vifmgr.portdown: A link down event was received on node ***, port e1a.net.ifgrp.lacp.link.inactive: ifgrp a0b, port e1a has transitioned to an inactive state. The interface group is in a degraded state.netif.linkDown: Ethernet e1a: Link down, check cable.
~
netif.linkUp: Ethernet e1b: Link up.
netif.linkUp: Ethernet e1a: Link up.
- The issue remains after confirming the cabling is good connected to that port.
- The issue remains after connecting the port to a different known working switch port.
- The issue remains after the card re-seat.