A800 e1a or e1b port down
Applies to
AFF A800
Issue
- Cluster e1a or HA Interconnect e1b port is down in
::> system node run -node node_name -command sysconfig -a
output. Example:
slot 1: Dual 40/100G Ethernet T62100-CR
e1a MAC Address: 00:07:43:51:03:00 (auto-unknown-fd-down)
e1b MAC Address: 00:07:43:51:03:08 (auto-unknown-fd-down)
Device Type: T6 2
Firmware Version: 1.24.12.0
Part Number: 110122860B1
Hardware Revision: 0
Serial Number: PT09190900
- The ONTAP event message system (EMS) report. Example:
Mon Apr 14 18:48:11 +0900 [node_name: intr: netif.linkDown:info]: Ethernet e0a: Link down, check cable.
- The issue remains after confirming the cabling is good connected to that port.
- The issue remains after connecting the port to a different known working switch port.
- The issue remains after the card re-seat.