Issue

  • ONTAP cluster node reboots unexpectedly:

Uncorrectable Machine Check Error at CPU8. SPR_UBOX Error: STATUS<0xba00000000000e0b>(VALID,UC,EN,MISCV,PCC,CESI(0),CERR_CNT(0),OTHER_INFO(0),MSCOD(0),MCACOD(0xe0b))MISC<0x000000009a280000>(BUS_LOG(0x9a),DEVICE_LOG(0x5),FUNCTION_LOG(0),SEGMENT_LOG(0)) IIO Machine Check from devices(s): .

  • A PCIe adapter, or the PCIe link to it, reported an uncorrectable hardware error.
  • The system responds with a controller disruption to protect data integrity; in an HA pair, the partner takes over so that client I/O continues.
  • In some cases the message does not list the failing device after "IIO Machine Check from devices(s):", so the hardware component that needs to be replaced cannot be identified from the message alone.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.