CONTAP-505435: BMC firmware reports "In Progress: No" with misleading values for "Percentage Done" field after BMC firmware update is completed
Issue
After BMC firmware update, the BMC version displays an update progress of 0% (instead of 100% or blank), despite the service processor being correctly updated and displaying an "End Time" time stamp for command "system service-processor image update-progress show:
Cluster-01::> system service-processor image update-progress show
In Percent
Node Progress Start Time Done End Time
---------------- -------- ------------------- ------- -------------------
Cluster-01-01 no 11/30/2024 21:35:31 0 11/30/2024 21:41:38
Cluster-01-02 no 11/30/2024 21:36:26 0 11/30/2024 21:42:34
Cluster-01-07 no 2/17/2025 10:05:03 100 2/17/2025 10:11:39
Cluster-01-08 no 2/17/2025 10:18:15 0 2/17/2025 10:26:21
4 entries were displayed. * Firmware update has completed successfully
- Firmware version displays correctly in node level (sysconfig-a), cluster level (system service-processor show, system service-processor image show) and BMC level (bmc status)
- The issue is not necessarily observed in every node of the cluster