  • Applies to AFF A250, AFF C250, ASA A250 or AFF A250 storage systems with motherboard Mfg. part number: 111-05257
  • The X1152 (4‑port 25GbE RoCE SFP28) NIC is in slot 1
  • ONTAP's NIC port mapping is incorrect for the ports in slot 1:
    • Physical port e1a maps to e1c in ONTAP
    • Physical port e1b maps to e1d in ONTAP
    • Physical port e1c maps to e1a in ONTAP
    • Physical port e1d maps to e1b in ONTAP
  • When a cable is plugged into physical e1a, network port show / sysconfig reports e1c as up while e1a remains down
  • Similar incorrect behavior occurs for the other three ports on both nodes.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.