CFLOADER-1805: New install: AFF-A250 slot 1 X1152 NICs have ports incorrectly mapped

Views:
1
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Issue

  • Initial installation and cluster setup of an AFF A250 HA pair

  • Both nodes have a 4‑port 25GbE RoCE SFP28 (X1152) NIC in slot 1.

  • Logical NIC port mapping is incorrect for slot‑1 ports:

    • Physical e1a shows up as e1c in software.

    • Physical e1b shows up as e1d in software.

    • Physical e1c shows up as e1a in software.

    • Physical e1d shows up as e1b in software.

  • When a cable is plugged into physical e1a, network port show / sysconfig report e1c as up while e1a remains down.

  • Similar incorrect behavior occurs for the other three ports on both nodes.

  • The mis‑mapping prevents correct cabling for cluster setup, so cluster setup cannot be completed.

  • Issue persists after:

    • Reseating/swapping cables and SFPs.

    • Rebooting and power‑cycling both nodes.

    • Swapping NIC cards between slots.

  • Behavior is identical on both nodes in the HA pair.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.