CFBMC-8909: Inconsistent power supply health status across ONTAP systems
Issue
When the power cable is disconnected from power supply on the AFF-A70 system, or when the power supply itself is removed,
The Environment health status remains as ok, despite critical alerts being logged for the power supply.
This issue is also found on other systems such as FAS70, AFF-A200 and AFF-C60, which can potentially lead to confusion or missed alerts for affected users.
The Environment health status remains as ok, despite critical alerts being logged for the power supply.
A70::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health ok
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node ok
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster ok
13 entries were displayed.This issue is also found on other systems such as FAS70, AFF-A200 and AFF-C60, which can potentially lead to confusion or missed alerts for affected users.