CFBMC-5427: AFF A400 and FAS8300 Multiple Internal Temp sensors are unreadable

Views:
204
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

Issue

  • event log show reports multiple sensor-unreadable errors.

node1 ALERT nvmem.battery.notPresent: The NVMEM battery is not present. To prevent data loss, the system will shut down in 5 minutes.
node1 ERROR callhome.chassis.ps.degraded: Call home for CHASSIS POWER SUPPLY DEGRADED: PS 1
node1 EMERGENCY monitor.globalStatus.critical: Power Supply Status Critical: PSU2, PSU1.
node1 EMERGENCY callhome.chassis.overtemp: Call home for CHASSIS OVER TEMPERATURE SHUTDOWN
node1 EMERGENCY callhome.battery.failure: Call home for BATTERY (not present) CRITICAL.
node1 ERROR callhome.chassis.power: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU2, PSU1.
node1 ALERT monitor.chassisPower.degraded: Chassis power is degraded: Power Supply Status Critical: PSU2, PSU1.
node1 EMERGENCY monitor.shutdown.chassisOverTemp: Chassis temperature is too hot: Multiple Internal Temp sensors are unreadable. System will be shutdown in 10 minutes

  • Multiple sensors are unavailable or invalid, and the serial console on the node is unresponsive.

::*> node run -node node1 -command environment status chassis list-sensors
Node: node1
Sensor Name State Current Critical Warning Warning Critical
 Reading Low Low High High
-------------------------------------------------------------------------------------------------
NVDIMM0 Health GOOD
LED1 Temp not_available -- C 0 C 3 C 43 C 46 C
LED2 Temp not_available -- C 0 C 3 C 43 C 46 C
MP Temp1 not_available -- C 0 C 5 C 45 C 48 C
MP Temp3 not_available -- C 0 C 5 C 45 C 48 C
Mezz Temp1 invalid -- C 0 C 5 C 80 C 85 C
Mezz Temp2 invalid -- C 0 C 5 C 54 C 57 C
PSU1 VIN invalid -- mV 90480 mV 93600 mV 261040 mV 263120 mV
PSU1 VOUT invalid -- mV 11336 mV 11440 mV 12948 mV 13156 mV
PSU1 Curr IIN invalid -- mA 0 mA -- 9984 mA 12012 mA
PSU1 IOUT invalid -- mA 0 mA -- 130000 mA 132000 mA
PSU1 PIN invalid -- mW 7100 mW 14200 mW 1611700 mW 1796300 mW
PSU1 POUT invalid -- mW 7100 mW 14200 mW 1611700 mW 1796300 mW
PSU1 Inlet invalid -- C 0 C -- 58 C 63 C
PSU1 Hot invalid -- C 0 C -- 100 C 105 C
PSU1 FB Hot invalid -- C 0 C -- 100 C 105 C
PSU1 FAN not_available -- RPM 800 RPM 1200 RPM -- --
PSU2 VIN invalid -- mV 90480 mV 93600 mV 261040 mV 263120 mV
PSU2 VOUT invalid -- mV 11336 mV 11440 mV 12948 mV 13156 mV
PSU2 Curr IIN invalid -- mA 0 mA -- 9984 mA 12012 mA
PSU2 IOUT invalid -- mA 0 mA -- 130000 mA 132000 mA
PSU2 PIN invalid -- mW 7100 mW 14200 mW 1611700 mW 1796300 mW
PSU2 POUT invalid -- mW 7100 mW 14200 mW 1611700 mW 1796300 mW
PSU2 Inlet invalid -- C 0 C -- 58 C 63 C
PSU2 Hot invalid -- C 0 C -- 100 C 105 C
PSU2 FB Hot invalid -- C 0 C -- 100 C 105 C
PSU2 FAN invalid -- RPM 800 RPM 1200 RPM -- --
Fan1_1 not_available -- RPM 600 RPM 900 RPM -- --
Fan1_2 not_available -- RPM 600 RPM 900 RPM -- --
Fan2_1 not_available -- RPM 600 RPM 900 RPM -- --
Fan2_2 not_available -- RPM 600 RPM 900 RPM -- --
Fan3_1 not_available -- RPM 600 RPM 900 RPM -- --
Fan3_2 not_available -- RPM 600 RPM 900 RPM -- --
Fan4_1 not_available -- RPM 600 RPM 900 RPM -- --
Fan4_2 not_available -- RPM 600 RPM 900 RPM -- --

  • Fan sensors may alternatively report No Reading.

Fan1_1 | 70h | ns | 29.1 | No Reading
Fan2_1 | 71h | ns | 29.2 | No Reading
Fan3_1 | 72h | ns | 29.3 | No Reading
Fan4_1 | 73h | ns | 29.4 | No Reading
Fan1_2 | 74h | ns | 29.1 | No Reading
Fan2_2 | 75h | ns | 29.2 | No Reading
Fan3_2 | 76h | ns | 29.3 | No Reading
Fan4_2 | 77h | ns | 29.4 | No Reading

  • From baseboard management controller (BMC) CLI bmc log debug output, several sensor statuses are na.

[2023-07-04 20:27:26.617] CX5_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 80.000 | 85.000 | na
[2023-07-04 20:27:26.617] CX5_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 80.000 | 85.000 | na
[2023-07-04 20:27:26.617] LED1_Temp | na | degrees C | na | na | 0.000 | 3.000 | 43.000 | 46.000 | na
[2023-07-04 20:27:26.617] LED2_Temp | na | degrees C | na | na | 0.000 | 3.000 | 43.000 | 46.000 | na
[2023-07-04 20:27:26.617] MP_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 45.000 | 48.000 | na
[2023-07-04 20:27:26.667] MP_Temp3 | na | degrees C | na | na | 0.000 | 5.000 | 45.000 | 48.000 | na
[2023-07-04 20:27:29.016] Mezz_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 80.000 | 85.000 | na
[2023-07-04 20:27:29.016] Mezz_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 54.000 | 57.000 | na

  • BMC may automatically reboot to recover the sensor state.

Fri Sep 05 14:58:08 +0900 [node01: env_mgr: monitor.shutdown.chassisOverTemp:EMERGENCY]: Chassis temperature is too hot: Multiple Internal Temp sensors are unreadable. System will be shutdown in 10 minutes
Fri Sep 05 14:58:24 +0900 [node01: env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
Fri Sep 05 14:58:24 +0900 [node01: env_mgr: sp.reboot.sensor.unreadable:notice]: Rebooting BMC because one or more sensors are unreadable.
Fri Sep 05 14:59:14 +0900 [node01: env_mgr: callhome.chassis.overtemp:EMERGENCY]: Call home for CHASSIS OVER TEMPERATURE SHUTDOWN

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.