ScriptExecution and Error Initialization failed during System Manager ONTAP upgrade
Applies to
- ANDU (Automated Non-Disruptive Upgrade)
- ONTAP 9
- System Manager
Issue
- When initiating an ONTAP upgrade from System Manager, validation fails
- Checking in ONTAP CLI (Command Line Interface), the follow error is seen
Cluster::> cluster image show-update-progress -instance
Upgrade Stage: Upgrade from <current ONTAP verison> to <target ONTAP version>
Update Phase: validation
Phase Status: paused-on-error
Phase Duration:
Phase Comments: 0 of 4 validated. Error: Internal error. Initialization failed, Action: Verify that all nodes are healthy using the "cluster show" command, then try the command again.
Elapsed duration of the phase: <time>
Estimated duration of the phase: <time>
Phase Description: Pre-update checks
Subsystem Name: ScriptExecution
Subsystem Status: Error
Subsystem Details: Error: Internal error. Initialization failed
Subsystem Action: Action: Verify that all nodes are healthy using the "cluster show" command, then try the command again
Status: Paused - An error occurred in "Pre-update checks" phase. The update cannot continue until the error has been resolved. Resolve all issues, then use the "cluster image resume-update" command to resume the update.
- The cluster is healthy with no alerts
Cluster::> cluster show
Cluster::> system health alert show