Skip to main content
NetApp Knowledge Base

Is it possible to shutdown both controllers of HA in ONTAP System Manager

Views:
115
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • ONTAP System Manager

Answer

  • Can't shutdown two nodes of HA in ONTAP System Manager.
  • Only one of the two nodes in the HA can be shutdown in ONTAP System Manager
  • Run the command to shutdown all nodes at the same time via CLI:
::> system node halt -node * -skip-lif-migration-before-shutdown true -ignore-quorum-warnings true -inhibit-takeover true -ignore-strict-sync-warnings true

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.