Issue

  • The CN1610 cluster switch shuts down.
  • Switch logs indicate shut down due to power loss:
Power supply state change alarm: Power Supply Unit: 1  ID: 1  Event: 5 - Power Loss

SW1-1 BSP[envMonTask]: cpu_boxs.c(1487) 719 %% Warning temperature reading : 60 deg C!
SW1-1 BSP[envMonTask]: cpu_boxs.c(1512) 726 %% Critical temperature reading : 61 deg C!
SW1-1 BSP[envMonTask]: cpu_boxs.c(2050) 727 %% Starting 2 minute shutdown timer !
SW1-1 BSP[envMonTask]: cpu_boxs.c(2095) 728 %% System shutting down !
  • If this issue happens on both cluster switches, then the cluster rings can be seen going offline which can further cause:
    • Nodes generating NODE(S) OUT OF CLUSTER QUORUM) EMERGENCY  autosupport.
    • Aggregates, volumes, LIFs etc may be listed as offline in the show outputs using CLI.
    • Nodes may not get listed properly (even if they are online).

cluster1::> node show

Node      Health Eligibility Uptime        Model       Owner   
--------- ------ ----------- ------------- ----------- --------
node-1    false  true                    - -           -       
node-2    false  true        71 days 19:42 FAS8060             
node-3    false  true                    - -           -       
node-4    false  true                    - -           -       
4 entries were displayed.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.