Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 61 results
    • https://kb.netapp.com/on-prem/Switches/NetApp-KBs/How_to_disable_and_enable_a_port_on_a_CN1610_switch
      Applies to Cluster Network Switch (CNS) CN1610 Description For troubleshooting purposes there might be a need to disable and enable a CN1610 switch port
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/How_to_configure_the_serviceport_on_a_CN1610_Cluster_Switch
      Applies to CN1610 Description This article provides minimal steps required in order to set up the Serviceport on the CN1610 as well as SSH in order to remotely access the switch.
    • https://kb.netapp.com/on-prem/Switches/NetApp-KBs/Terrapin_Vulnerability_on_CN1610
      Applies to Fastpath 1.3.0.3 Fastpath 1.3.0.2 CN1610 Issue Qualys detecting Terrapin Vulnerability (CVE-2023-48795) on CN1610
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/VIFMGR_offline_migrating_cluster_switch_CN1610_to_BES-53248
      Wed Jun 23 2021 09:28:08 +02:00 [kern_vifmgr:info:7192] [0x80bae2900] [FailoverMgr::cluster_check] l2ping failed e0a on node1 -> e0c on node2 result='remote interface is down or unreachable. Wed Jun 2...Wed Jun 23 2021 09:28:08 +02:00 [kern_vifmgr:info:7192] [0x80bae2900] [FailoverMgr::cluster_check] l2ping failed e0a on node1 -> e0c on node2 result='remote interface is down or unreachable. Wed Jun 23 2021 09:28:33 +02:00 [kern_vifmgr:info:7192] [0x80bae2900] [FailoverMgr::cluster_check] l2ping failed e0a on node1 -> e0c on node2 result='remote interface is down or unreachable.
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/How_to_reboot_a_cluster_interconnect_switch
      Applies to ONTAP Cluster interconnect switches NetApp CN1610 Broadcom BES-53248 Cisco Nexus 3132Q-V Cisco Nexus 3232C Cisco Nexus 5596 Cisco Nexus 92300YC Cisco Nexus N9K-C9336C-FX2 Description How to...Applies to ONTAP Cluster interconnect switches NetApp CN1610 Broadcom BES-53248 Cisco Nexus 3132Q-V Cisco Nexus 3232C Cisco Nexus 5596 Cisco Nexus 92300YC Cisco Nexus N9K-C9336C-FX2 Description How to reboot a cluster interconnect switch.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/CN1610_Switch_cannot_be_reached_remotely_and_non_responsive_to_SNMP
      Applies to CN1610 Cluster Switch Issue CN1610 Switch cannot be reached remotely and may be non-responsive when consoled into the switch. Upon entering switch credentials in SSH session, the session ha...Applies to CN1610 Cluster Switch Issue CN1610 Switch cannot be reached remotely and may be non-responsive when consoled into the switch. Upon entering switch credentials in SSH session, the session hangs indefinitely.
    • https://kb.netapp.com/on-prem/Switches/NetApp-KBs/CN1610_not_detecting_new_DHCP_IP_when_migrated_to_new_network
      Applies to CN1610 Cluster switch CN1610 is migrated from one management subnet to a different one management interface does not automatically receive a DHCP IP address Switch log shows <13> Apr 15 23:...Applies to CN1610 Cluster switch CN1610 is migrated from one management subnet to a different one management interface does not automatically receive a DHCP IP address Switch log shows <13> Apr 15 23:30:17 switch-1 DHCP_CLI[osapiTimer]: dhcp_prot.c(784) 51998 %% Failed to acquire an IP address on Network Port; DHCP Server did not respond. <13> Apr 15 23:25:14 switch-1 DHCP_CLI[osapiTimer]: dhcp_prot.c(784) 51996 %% Failed to acquire an IP address on Network Port; DHCP Server did not respond.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Cluster_Switch_health_monitoring_CSHM_not_working_IP_address_not_reachable_via_SNMP
      Applies to ONTAP 9 Cluster Switches (Interconnect and Management) Issue Cluster not able monitor health status of the cluster network switches The following outputs may be seen: cluster::system cluste...Applies to ONTAP 9 Cluster Switches (Interconnect and Management) Issue Cluster not able monitor health status of the cluster network switches The following outputs may be seen: cluster::system cluster-switch> show Switch Type Address Model node1 cluster-network xx.xx.xx.xx CN1610 node2 cluster-network xx.xx.xx.xx CN1610 Serial Number: serial_number Is Monitored: false Reason: IP Address not reachable via SNMP Software Version: NetApp CN1610, 1.3.0.3, Linux 3.8.13-2de1cc1c Version Source: SNMP
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/broad_hpc_drv_c_4428_error_on_Cluster_switch_CN1610
      Applies to CN1610 Issue Repeated error on CN1610 logging: <11> Jun 9 21:49:53 cn1610_switch DRIVER[bcmDPC]: broad_hpc_drv.c(4428) 121812 %% unit = 0, EGR_L3_NEXT_HOP.Y, entry 0 parity error <11> Jun 9...Applies to CN1610 Issue Repeated error on CN1610 logging: <11> Jun 9 21:49:53 cn1610_switch DRIVER[bcmDPC]: broad_hpc_drv.c(4428) 121812 %% unit = 0, EGR_L3_NEXT_HOP.Y, entry 0 parity error <11> Jun 9 21:49:52 cn1610_switch DRIVER[bcmDPC]: broad_hpc_drv.c(4428) 121811 %% unit = 0, EGR_L3_NEXT_HOP.Y, entry 0 parity error
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/After_switch_reboot_CLUSTER_NETWORK_DEGRADED_ALERT_seen_SwitchIfIslDownWarn_Alert
      After every cluster switch reboot, AutoSupport generates CLUSTER NETWORK DEGRADED and SwitchIfIslDownWarn_Alert errors. The Switch-Health in system health subsystem show reports degraded.
    • https://kb.netapp.com/on-prem/Switches/NetApp-KBs/How_to_configure_RADIUS_on_CN1610_and_CN1601_switches
      Applies to NetApp CN1610 NetApp CN1601 Description Configure CN1610 / CN1601 for RADIUS.