Cisco Nexus 5596 Cluster switch reboots and is hung
Applies to
- Cisco Nexus 5596 cluster switches
- ONTAP 9
- AFF/FAS
Issue
- Cisco Nexus 5596 switch reboots and the following alerts are seen in event logs:
[Node-1: cshmd: hm.alert.raised:alert]: Alert Id = SwitchIfIslDownWarn_Alert , Alerting Resource = sw01(XXXXXXXXXX)/port-channel1 raised
[Node-1: cshmd: hm.alert.raised:alert]: Alert Id = ClusterSwitchMissing_Alert , Alerting Resource = Node-1 raised by monitor cluster-switch].
[Node-1: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: ClusterSwitchMissing_Alert[Node-1 by monitor cluster-switch]
- The switch boots up only after a power cycle and after the reboot,
ClusterSwitchMissing_Alert
is cleared:
[Node-1: cshmd: hm.alert.raised:alert]: Alert Id = SwitchReboot_Alert , Alerting Resource = sw02(XXXXXXXXX) raised by monitor cluster-switch
[Node-1: cshmd: hm.alert.cleared:notice]: Alert Id = ClusterSwitchMissing_Alert , Alerting Resource = Node-1 cleared by monitor cluster-switch
[Node-1: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchReboot_Alert , Alerting Resource = sw02(XXXXXXXXX) cleared by monitor cluster-switch