Switch Blade reported faulty on a Brocade Director Switch
Applies to
Brocade X6-8
Issue
- All the ports on the switch blade are disabled or not displaying
<<switchshow output truncated>>
Index Slot Port Address Media Speed State Proto
============================================================
96 11 0 0c6040 -- UN N/A FC Disabled
97 11 1 0c6140 -- UN N/A FC Disabled
98 11 2 0c6240 -- UN N/A FC Disabled
99 11 3 0c6340 -- UN N/A FC Disabled
100 11 4 0c6440 -- UN N/A FC Disabled
101 11 5 0c6540 -- UN N/A FC Disabled
102 11 6 0c6640 -- UN N/A FC Disabled
103 11 7 0c6740 -- UN N/A FC Disabled
104 11 8 0c6840 -- UN N/A FC Disabled
- errdump reports blade state faulty
2022/03/15-05:46:45, [MAPS-1002], 115038, SLOT 1 | FID 128, ERROR, SWITCH1, Blade 11, Condition=ALL_SLOTS(BLADE_STATE==FAULTY), Current Value:[BLADE_STATE, FAULTY], RuleName=defALL_SLOTSBLADE_STATE_FAULTY, Dashboard Category=Fru Health.
- slotshow reports the blade faulty
CHASSISCMD /fabos/cliexec/slotshow -m:
Tue Mar 15 07:01:03 IST 2022
********************************************************
/fabos/cliexec/slotshow -m:
Slot Blade Type ID Model Name Status
--------------------------------------------------
1 CP BLADE 175 CPX6 ENABLED
2 CP BLADE 175 CPX6 ENABLED
3 SW BLADE 178 FC32-48 ENABLED
4 SW BLADE 178 FC32-48 ENABLED
5 SW BLADE 178 FC32-48 ENABLED
6 SW BLADE 178 FC32-48 ENABLED
7 CORE BLADE 177 CR32-8 ENABLED
8 CORE BLADE 177 CR32-8 ENABLED
9 SW BLADE 178 FC32-48 ENABLED
10 SW BLADE 178 FC32-48 ENABLED
11 SW BLADE 178 FC32-48 FAULTY (21)
12 SW BLADE 178 FC32-48 ENABLED