One of the ISL link down on BES cluster switch
Applies to
- ONTAP 9
- BES-53248 Cluster Switch
Issue
- The system reports SwitchIslIfDownWarn_Alert alert in event logs
Mon Aug 25 12:26:21 -0700 [node1: cshmd: hm.alert.raised:alert]: Alert Id = SwitchIslIfDownWarn_Alert , Alerting Resource = switch2/Slot: 0 Port: 56 100G - Level cleared by monitor ethernet-switch
- System health reports the following
Detailed Problem Description: Node: Node1 Alert ID: SwitchIslIfDownWarn_Alert Resource: Slot: 0 Port: 56 100G - Level Severity: Major Indication Time: Thu Jan 15 11:57:07 2026 Suppress: false Acknowledge: false Probable Cause: The cable attached to the ISL port "switch1/Slot: 0 Port: 56 100G - Level" with the description of "Cluster ISL Port" might be faulty. For the port-channel, please check each individual link. Possible Effect: Inter- or Intra- cluster redundancy might be lost.Corrective Actions: 1) Check whether the cable is fully inserted into the interface port on both ends. 2) Reconnect the ISL port using another cable. After reconnecting it, verify whether the link of the ISL port is up by executing the commands per the switch configuration guide or by checking whether the Link status LED is on.
- Switch logs reports the ISL link to be down
*************** show port all *************** Admin Physical Physical Link Link LACP ActorIntf Type Mode Mode Status Status Trap Mode Timeout--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/55 PC Mbr Enable Auto 100G Full Up Enable Enable long0/56 PC Mbr Enable Auto Down Enable Enable long