One of the ISL link down on BES cluster switch
Applies to
- ONTAP 9
- BES-53248 Cluster Switch
Issue
- The system reports SwitchIslIfDownWarn_Alert alert in event logs
[?] Mon Nov 03 00:42:36 +0530 [node1: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchIslIfDownWarn_Alert , Alerting Resource = switch2/Slot: 0 Port: 56 100G - Level cleared by monitor ethernet-switch
- Switch logs where ISL link on port reports down
0/55 PC Mbr Enable 100G Full 100G Full Up Enable Enable long 0/56 PC Mbr Enable 100G Full Down Enable Enable long Log. Channel Admin Mbr Device/ Port Port Intf Name Min Link Mode Type Ports Timeout Speed Active ------- --------------- ---- ------ ------ ---- ------- ------------- --------- ------- 1/1 Cluster-ISL 1 Up En. Dyn. 0/55 actor/long 100G Full True partner/long 0/56 actor/long 100G Full False partner/long
- Reseating cable and performing shut/no shut of port does not resolve issue.