Ongoing FC_PORT_ERRORS_THRESHOLD_CROSSED events on NetApp-supplied Brocade switches
Applies to
- Brocade switch
- G630
- Dense Wavelenth Division Multiplexing (DWDM)
Issue
FC_PORT_ERRORS_THRESHOLD_CROSSEDalerts received for Brocade switch ports.- Hosts connected to these switches are experiencing performance degradation.
- No errors reported on storage array connections.
errdumpshows huge number of errors:
2026/02/08-17:23:16:632367 (GMT), [C5-1044], 7218/3814, CHASSIS, INFO, xxxx, Trunk performance impact on port (xx) due to high deskew value. [TRUNK_PERF:40 percent, Deskew:169], OID:0x43010880, SPOID:xxxx, c5_txxxksm.c, line: 9128, comp:emd, ltime:2026/02/08-17:23:16:6318402026/02/02-09:14:56 (GMT), [C5-1044], 3135, CHASSIS, INFO, xxxx, Trunk performance impact on port (xx) due to high deskew value. [TRUNK_PERF:59 percent, Deskew:114]