HA state went out of sync due to mdd process restart on Brocade switch
Applies to
- FOS V9.2.1A
- Brocade X-series switch
Issue
- HA State went out of sync for Brocade X-series switch with FOS v9.2.1a.
- Along with out of sync event ffdc & md process restart events seen in errdump.
2025/09/14-23:15:27 (IST), [KSWD-1002], 3221820, SLOT 2 | FFDC | CHASSIS, WARNING,sw7, Detected termination of process mdd:3644.
2025/09/14-23:15:27 (IST), [RAS-1001], 3221821, SLOT 2 | CHASSIS, INFO, sw7, First failure data capture (FFDC) event occurred.
2025/09/14-23:15:50 (IST), [FSSM-1003], 3221822, SLOT 1 | CHASSIS, WARNING, sw7, HA State out of sync.
2025/09/14-23:16:04 (IST), [FSSM-1003], 3221823, SLOT 2 | CHASSIS, WARNING, sw7, HA State out of sync.
2025/09/14-23:16:15 (IST), [USWD-1002], 3221824, SLOT 2 | CHASSIS, INFO, sw7, System component fcsw:md restart completed.
2025/09/14-23:16:30 (IST), [MAPS-1145], 3221825, SLOT 2 | FID 128, INFO, sw7, FPI Profile dflt_fpi_profile is activated for E-Ports.
2025/09/14-23:16:30 (IST), [MAPS-1144], 3221826, SLOT 2 | FID 128, INFO, sw7, FPI Profile dflt_fpi_profile is activated for F-Ports.
2025/09/14-23:16:30 (IST), [MAPS-1201], 3221827, SLOT 2 | FID 128, INFO, sw7, MAPS has started monitoring with dflt_moderate_policy policy.
2025/09/14-23:16:30 (IST), [FSSM-1002], 3221828, SLOT 2 | CHASSIS, INFO, sw7, HA State is in sync.
2025/09/14-23:16:30 (IST), [FSSM-1002], 3221829, SLOT 1 | CHASSIS, INFO, sw7, HA State is in sync.