Skip to main content
NetApp Knowledge Base

Brocade switch port flaps without any media errors reported

Views:
497
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

Brocade Switch

Issue

  • Brocade switch port flaps without any media errors being reported under porterrshow.
  • Switchshow reports the port as online
 
/fabos/bin/switchshow :
switchName: BROCADEXX
switchType: 166.0
switchState: Online
switchMode: Native
Index Slot Port Address Media  Speed        State    Proto
============================================================
240   12   16   67f040   id    N16   Online      FC  F-Port  x1:00:00:24:ff:1d:xx:xy
 
 
 
/fabos/cliexec/porterrshow :
frames        enc     crc     crc     too     too     bad     enc    disc    link    loss    loss    frjt    fbsy     c3timeout     pcs      uncor
tx       rx      in     err     g_eof   shrt    long    eof     out    c3      fail    sync    sig                      tx      rx      err     err
240:    2.5k    2.5k    0       0       0       0       0       0       0       0       5       0       5       0       0       0       0       0       0
 
 
  • Fabriclog shows the port flapping happened just once:
04:14:47.513170 SCN Port Offline;rsn=0x4,g=0x20             A2,P0  A2,P0  240   NA
04:14:47.513177 *Removing all nodes from port               A2,P0  A2,P0  240   NA
04:14:47.000670 SCN LR_PORT(0);g=0x5ea                      A2,P0  A2,P0  240   NA
04:14:47.065831 SCN Port Online; g=0x5ea,isolated=0         A2,P0  A2,P1  240   NA
04:14:47.065910 Port Elp engaged                            A2,P1  A2,P0  240   NA
04:14:47.065920 *Removing all nodes from port               A2,P0  A2,P0  240   NA
04:14:47.066147 SCN Port F_PORT                             A2,P1  A2,P0  240   NA
 
 
  • SFP TX and RX power are within the recommended range under sfpshow 
=============
Slot 12/Port 16:
=============
 
RX Power:    -2.8    dBm (528.3uW)
TX Power:    -1.7    dBm (677.0 uW)
 
  • Portshow displays Lr-in greater than Ols_out

Lr_in:             1       Ols_in:       0
Lr_out:            0       Ols_out:      0

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.