Skip to main content
NetApp Knowledge Base

Brocade switch port flaps with minimal media errors being reported

Views:
286
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

Brocade Switch

Issue

  • Brocade switch port flaps with minimal media errors being reported under porterrshow such as link fail, loss sig, uncorr and pcs errors on both the fabrics around same timestamp.

/fabos/cliexec/porterrshow :
          frames        enc     crc     crc     too     too     bad     enc    disc    link    loss    loss    frjt    fbsy     c3timeout     pcs      uncor
        tx       rx      in     err     g_eof   shrt    long    eof     out    c3      fail    sync    sig                      tx      rx      err     err
346:  461.7m   94.4m    0       0       0       0       0       0       0       0       4       0       2       0       0       0       0     255       0

108:  447.8m  117.4m    0       0       0       0       0       0       0       0       1       0       1       0       0       0       0       0       3
 

  • Switchshow reports the port as online

/fabos/bin/switchshow :
Index Slot Port Address Media  Speed        State    Proto
============================================================
346   10   42   6bd2c0   id    N16   Online      FC  F-Port  21:00:00:24:cc:xx:yy:zz

  • "Loss of sync" events logged under errdump:

2023/12/24-05:53:33:343947 (IST), [C4-5040], 2014234/0, SLOT 2 | CHASSIS | PORT 11/12, INFO, Switch, Link loss of sync debouncing event detected: Slot 11/Port 108(124) Event=dead0bee Tov_Val=64., OID:0x43b28abc, SPOID:0x43b68xxx, c4_intr.c, line: 3849, comp:insmod, ltime:2023/12/24-05:53:33:343631

  • Fabriclog shows the port flapping happened just twice

Switch 0; Sat Apr  1 01:00:34 2023 IST (GMT+5:30)
01:00:34.971674 SCN Port Offline;rsn=0x4,g=0xe5a            A2,P0  A2,P0  346   NA
01:00:34.971681 *Removing all nodes from port               A2,P0  A2,P0  346   NA
01:00:34.984155 SCN LR_PORT(0);g=0xe5a                      A2,P0  A2,P0  346   NA
01:00:35.091854 SCN Port Online; g=0xe5a,isolated=0         A2,P0  A2,P1  346   NA
01:00:35.093200 Port Elp engaged                            A2,P1  A2,P0  346   NA
01:00:35.093218 *Removing all nodes from port               A2,P0  A2,P0  346   NA
01:00:35.093446 SCN Port F_PORT                             A2,P1  A2,P0  346   NA
01:01:39.564758 SCN Port Offline;rsn=0x2,g=0xe5c            A2,P0  A2,P0  346   NA
01:01:39.564764 *Removing all nodes from port               A2,P0  A2,P0  346   NA
01:01:41.783142 SCN LR_PORT(0);g=0xe5c                      A2,P0  A2,P0  346   NA
01:01:41.842466 SCN Port Online; g=0xe5c,isolated=0         A2,P0  A2,P1  346   NA
01:01:41.842556 Port Elp engaged                            A2,P1  A2,P0  346   NA
01:01:41.842568 *Removing all nodes from port               A2,P0  A2,P0  346   NA
01:01:41.842844 SCN Port F_PORT                             A2,P1  A2,P0  346   NA

  • Tx and Rx power are in optimal range on the switch end sfp.

=============
Slot 11/Port 12:
=============
Temperature: 59      Centigrade
Current:     7.496   mAmps
Voltage:     3306.8  mVolts
RX Power:    -1.7    dBm (677.8uW)
TX Power:    -0.2    dBm (959.7 uW)

  • Tx value is optimal but Rx is value is slightly low and is near to the threshold value under sfpshow.

Slot 10/Port 42:
=============
Identifier:  3    SFP
Connector:   7    LC
Transceiver: 6804406000000000 8,16,32_Gbps M5 sw Inter,Short_dist
[..]
Vendor Name: BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   57-1000333-01
[..]
Temperature: 57      Centigrade
Current:     6.026   mAmps
Voltage:     3295.9  mVolts
RX Power:    -4.1    dBm (392.6uW)
TX Power:    -1.7    dBm (683.9 uW)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.