Brocade switch port flaps with minimal media errors being reported
Applies to
Issue
- Brocade switch port flaps with minimal media errors being reported under
porterrshow
such aslink fail, loss sig, uncorr
andpcs
errors on both the fabrics around same timestamp.
/fabos/cliexec/porterrshow :
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err
346: 461.7m 94.4m 0 0 0 0 0 0 0 0 4 0 2 0 0 0 0 255 0
108: 447.8m 117.4m 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 3
Switchshow
reports the port as online
/fabos/bin/switchshow :
Index Slot Port Address Media Speed State Proto
============================================================
346 10 42 6bd2c0 id N16 Online FC F-Port 21:00:00:24:cc:xx:yy:zz
- "Loss of sync" events logged under
errdump
:
2023/12/24-05:53:33:343947 (IST), [C4-5040], 2014234/0, SLOT 2 | CHASSIS | PORT 11/12, INFO, Switch, Link loss of sync debouncing event detected: Slot 11/Port 108(124) Event=dead0bee Tov_Val=64., OID:0x43b28abc, SPOID:0x43b68xxx, c4_intr.c, line: 3849, comp:insmod, ltime:2023/12/24-05:53:33:343631
Fabriclog
shows the port flapping happened just twice
Switch 0; Sat Apr 1 01:00:34 2023 IST (GMT+5:30)
01:00:34.971674 SCN Port Offline;rsn=0x4,g=0xe5a A2,P0 A2,P0 346 NA
01:00:34.971681 *Removing all nodes from port A2,P0 A2,P0 346 NA
01:00:34.984155 SCN LR_PORT(0);g=0xe5a A2,P0 A2,P0 346 NA
01:00:35.091854 SCN Port Online; g=0xe5a,isolated=0 A2,P0 A2,P1 346 NA
01:00:35.093200 Port Elp engaged A2,P1 A2,P0 346 NA
01:00:35.093218 *Removing all nodes from port A2,P0 A2,P0 346 NA
01:00:35.093446 SCN Port F_PORT A2,P1 A2,P0 346 NA
01:01:39.564758 SCN Port Offline;rsn=0x2,g=0xe5c A2,P0 A2,P0 346 NA
01:01:39.564764 *Removing all nodes from port A2,P0 A2,P0 346 NA
01:01:41.783142 SCN LR_PORT(0);g=0xe5c A2,P0 A2,P0 346 NA
01:01:41.842466 SCN Port Online; g=0xe5c,isolated=0 A2,P0 A2,P1 346 NA
01:01:41.842556 Port Elp engaged A2,P1 A2,P0 346 NA
01:01:41.842568 *Removing all nodes from port A2,P0 A2,P0 346 NA
01:01:41.842844 SCN Port F_PORT A2,P1 A2,P0 346 NA
- Tx and Rx power are in optimal range on the switch end sfp.
=============
Slot 11/Port 12:
=============
Temperature: 59 Centigrade
Current: 7.496 mAmps
Voltage: 3306.8 mVolts
RX Power: -1.7 dBm (677.8uW)
TX Power: -0.2 dBm (959.7 uW)
- Tx value is optimal but Rx is value is slightly low and is near to the threshold value under
sfpshow
.
Slot 10/Port 42:
=============
Identifier: 3 SFP
Connector: 7 LC
Transceiver: 6804406000000000 8,16,32_Gbps M5 sw Inter,Short_dist
[..]
Vendor Name: BROCADE
Vendor OUI: 00:05:1e
Vendor PN: 57-1000333-01
[..]
Temperature: 57 Centigrade
Current: 6.026 mAmps
Voltage: 3295.9 mVolts
RX Power: -4.1 dBm (392.6uW)
TX Power: -1.7 dBm (683.9 uW)