Brocade switch port online and report low Rx due to faulty switch end SFP
Applies to
Brocade switch
Issue
- Lox Rx reported on the switch port
RX Power: -9.1 dBm (122.7uW)
TX Power: -1.3 dBm (736.1 uW)
- CRC and CRC G_EOF are reported along with pcs error
/fabos/cliexec/porterrshow :
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err
8: 1.6t 463.1g 0 48.5k 47.8k 2 0 674 0 467 12 0 17 0 0 0 0 489 0
- DB instances are getting failed and failed over to redundant node
- Below troubleshooting steps can be performed before proceeding to the solution:
- End to end cable testing, replace the cable if its faulty
- Replace the host end SFP