BES-53248 ISL down when upgrading to EFOS 3.7.0.4 or later
Applies to
- Cluster Interconnect Switch
- Broadcom BES-53248 Switch
- Non-MetroCluster Switch
- EFOS upgrade to 3.7.0.4 and later
Issue
- Inter-Switch Links (ISLs) and port channel marked as
Down
, after upgrading one BES-53248 Cluster Network Switch to EFOS 3.7.0.4 or later
# show port-channel all
Log. Channel Admin Mbr Device/ Port Port
Intf Name Min Link Mode Type Ports Timeout Speed Active
------- --------------- ---- ------ ------ ---- ------- ------------- --------- -------
1/1 Cluster-ISL 1 Down En. Dyn. 0/55 actor/long 100G Full False
partner/long
0/56 actor/long 100G Full False
partner/long
# show port all
Admin Physical Physical Link Link LACP Actor
Intf Type Mode Mode Status Status Trap Mode Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/1 Enable 10G Full 10G Full Up Enable Enable long
0/2 Enable 10G Full 10G Full Up Enable Enable long
0/3 Enable 10G Full 10G Full Up Enable Enable long
0/4 Enable 10G Full 10G Full Up Enable Enable long
....
0/55 PC Mbr Enable 100G Full Down Enable Enable long
0/56 PC Mbr Enable 100G Full Down Enable Enable long
- AutoSupport generates alerts reporting switch ISLs are down, similar to:
HA Group Notification (Health Monitor process cshm: SwitchIfIslDownWarn_Alert[SW1/Slot: 0 Port: 55 100G - Level]) ALERT
HA Group Notification (Health Monitor process cshm: SwitchIfIslDownWarn_Alert[SW2/ Link Aggregate 1]) ALERT
- If cluster LIFs are manually reverted to home ports with cluster interconnect ISLs down, node on which cluster LIFs were reverted has outage (LIFs and volumes on this node will not serve data) and its cluster apps go offline on that node