Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 43 results
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/BES-53248_RCF_configuration_validation_fails_while_copying_the_script
      BES 53248 cluster switch reports validation error while trying to copy the RCF script: Line 55:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit Line 59:: police-simpl...BES 53248 cluster switch reports validation error while trying to copy the RCF script: Line 55:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit Line 59:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit Line 68:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit Line 72:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/Are_Broadcom_BES-53248_switches_supported_with_NetApp_HCI
      Broadcom BES-53248 switches do not support separate bonding modes on different switch ports. Non-redundant ports: Ports on either of the peer switches that are not part of the VPC (ports P4 and S4). V...Broadcom BES-53248 switches do not support separate bonding modes on different switch ports. Non-redundant ports: Ports on either of the peer switches that are not part of the VPC (ports P4 and S4). VPC interfaces and non-redundant ports cannot be members of the same VLAN, i.e. a VLAN may contain VPC interfaces or a VLAN may contain non-redundant ports, but not both. In the case where all VPC member ports are UP, data traffic does not traverse the peer link.
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/BES-53248_RCF_configuration_validation_fails_while_applying_the_script
      Following lines in the script may have problem: Line 55:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit Line 59:: police-simple rate-percent 60 64 conform-action tra...Following lines in the script may have problem: Line 55:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit Line 59:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit Line 68:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit Line 72:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit The file being downloaded has potential problems.
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/Some_RDBs_offline_in_one_node_when_upgrading_a_BES-53248_cluster_network_switch
      Node UnitName Epoch DB Epoch DB Trnxs Master Online --------- -------- -------- -------- -------- --------- --------- node_name-01 mgmt 22 22 2973276 node_name-02 secondary node_name-01 vldb 0 20 7455...Node UnitName Epoch DB Epoch DB Trnxs Master Online --------- -------- -------- -------- -------- --------- --------- node_name-01 mgmt 22 22 2973276 node_name-02 secondary node_name-01 vldb 0 20 745598 - offline node_name-01 vifmgr 0 22 2879331 - offline node_name-01 bcomd 20 20 465 node_name-02 secondary node_name-01 crs 20 20 60 node_name-02 secondary node_name-02 mgmt 22 22 2973276 node_name-02 master node_name-02 vldb 20 20 745602 node_name-02 master node_name-02 vifmgr 22 22 2879331 node_…
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/Where_to_find_MIB_files_for_Broadcom_BES-53248_switches
      DISMAN-PING-MIB The Ping MIB (DISMAN-PING-MIB) provides the capability of controlling the use of the ping function at a remote host. DNS-RESOLVER-MIB The MIB module for entities implementing the clien...DISMAN-PING-MIB The Ping MIB (DISMAN-PING-MIB) provides the capability of controlling the use of the ping function at a remote host. DNS-RESOLVER-MIB The MIB module for entities implementing the client (resolver) side of the Domain Name System (DNS) protocol. DNS-SERVER-MIB The MIB module for entities implementing the server side of the Domain Name System (DNS) protocol.
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/How_to_collect_data_from_a_BES-53248_switch
      Applies to Broadcom Ethernet Switch purchased from NetApp BES-53248 (X190005, X190005R) BES-53248-B (X190005-B, X190005R-B) Description This article describes how to collect data from a Broadcom BES-5...Applies to Broadcom Ethernet Switch purchased from NetApp BES-53248 (X190005, X190005R) BES-53248-B (X190005-B, X190005R-B) Description This article describes how to collect data from a Broadcom BES-53248 or BES-53248-B switch.
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/Intermittent_SwitchFanFail_Alert_messages_reported_for_BES-53248_switch
      <189> Nov 8 22:07:29 cs2-1 TRAPMGR[boxs_Req]: traputil.c(763) 129329 %% NOTE Fan state change alarm: Unit: 1 Fan ID: 11 Event: 3 - Operational <189> Nov 8 22:07:26 cs2-1 TRAPMGR[boxs_Req]: traputil.c(...<189> Nov 8 22:07:29 cs2-1 TRAPMGR[boxs_Req]: traputil.c(763) 129329 %% NOTE Fan state change alarm: Unit: 1 Fan ID: 11 Event: 3 - Operational <189> Nov 8 22:07:26 cs2-1 TRAPMGR[boxs_Req]: traputil.c(763) 129327 %% NOTE Fan state change alarm: Unit: 1 Fan ID: 11 Event: 4 - Failure <189> Nov 8 22:01:17 cs2-1 TRAPMGR[boxs_Req]: traputil.c(763) 129325 %% NOTE Fan state change alarm: Unit: 1 Fan ID: 11 Event: 3 - Operational
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/Broadcom_BES_53248_switch_not_booting_even_after_power_cycle
      Switch is not booting up. blk_update_request: I/O error, dev sda, sector 796936 [79952817.263167] blk_update_request: I/O error, dev sda, sector [79952817.270482] blk_update_request: I/O error, dev sd...Switch is not booting up. blk_update_request: I/O error, dev sda, sector 796936 [79952817.263167] blk_update_request: I/O error, dev sda, sector [79952817.270482] blk_update_request: I/O error, dev sda, sector 796944 previous I/O error to superblock detected [79952817.299208] blk_update_request: I/O error, dev sda, sector 788480 blk_update_request: I/O error, dev sda, sector 788480 [79952817.313458] Buffer I/O error on dev sda3, logical block 0, lost sync
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/Cluster_switch_log_collection_not_supported_aborting_for_BES_53248_switch
      Manual switch log collection fails with the following error: clusterswitch-01Error: Cluster switch log collection not supported - aborting. Corrective Actions: 1) To set up public SSH key authenticati...Manual switch log collection fails with the following error: clusterswitch-01Error: Cluster switch log collection not supported - aborting. Corrective Actions: 1) To set up public SSH key authentication on the Ethernet switch, run the "system switch ethernet log setup-password" command. 2) If public SSH key authentication is already configured, log in to the Ethernet switch Possible Effect: Ethernet switch tech-support logs are not available in AutoSupport(R) messages for troubleshooting.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/Command_mapping_between_Cisco_and_NVIDIA_switches
      nv show --paginate on|off nv show --paginate on system nv show system nv show platform nv show platform environment nv show platform hardware show ip interface mgmt 0 nv show interface mgmt show runni...nv show --paginate on|off nv show --paginate on system nv show system nv show platform nv show platform environment nv show platform hardware show ip interface mgmt 0 nv show interface mgmt show running-config interface ethernet 1/9 nv show interface <if_name> nv show interface swp3 nv show interface neighbor nv show interface nv show interface --view=pluggables nv config show nv config show -o commands nv config show --startup -o commands nv config show --rev=startup
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/No_authentication_via_ssh_to_the_Broadcom_BES-53248_switch
      Applies to Broadcom BES-53248 switch Secure Shell (SSH) login Issue admin user able to log onto the Switch via serial console, but can no longer authenticate via SSH. Access denied returned after logi...Applies to Broadcom BES-53248 switch Secure Shell (SSH) login Issue admin user able to log onto the Switch via serial console, but can no longer authenticate via SSH. Access denied returned after login password is entered. Example: admin@switch01's password: Access denied SSH login locked for the ‘admin’ user. user: SWITCH01-1 USER_MGR[tRpcsrv.01001]: user_mgr.c(2358) 944 %% ALRT User admin locked out on unsuccessful authentication