Event Summary

E-Series controller locked down due to submodel ID mismatch. This lock down indicates the presence of hardware mismatch between the two controllers.

Validate

  • The digital display code on the controller would report OE L7
  • In the event visual validation of the display code is not possible, the following command can be executed on the alternate online controller using eos user and the SANtricity System Manager admin password to confirm the lock down reason: cmgrShow

{
    "altCtlSystemInfo": {
        "lockdownInfo": {
            "additionalData": "",
            "ledSequence": "OEL7",
            "lockdownCause": 20,
            "lockdownCauseString": "LOCKDOWN_CAUSE_SMID_MISMATCH"
        }

Resolution

  • Check the part number of both controllers and determine if they match. There is likely a mismatch between the two controllers in the system.
  • Please contact NetApp Technical Support and reference this article for further assistance. 

 

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.