E-Series Controller submodel mismatch - AutoSupport Message
- Views:
- 14
- Visibility:
- Public
- Votes:
- 0
- Category:
- e-series-systems
- Specialty:
- esg
- Last Updated:
- 5/22/2025, 7:08:24 AM
Applies to
- NetApp E-Series.
- NetApp StorageGRID Appliances.
Event Summary
E-Series controller locked down due to submodel ID mismatch. This lock down indicates the presence of hardware mismatch between the two controllers.
Validate
- The digital display code on the controller would report
OE L7
. - In the event visual validation of the display code is not possible, the following command can be executed on the alternate online controller using eos user and the SANtricity System Manager admin password to confirm the lock down reason:
cmgrShow
{
"altCtlSystemInfo": {
"lockdownInfo": {
"additionalData": "",
"ledSequence": "OEL7",
"lockdownCause": 20,
"lockdownCauseString": "LOCKDOWN_CAUSE_SMID_MISMATCH"
}
Resolution
- Check the part number of both controllers and determine if they match. There is likely a mismatch between the two controllers in the system.
- Please contact NetApp Technical Support and reference this article for further assistance.
Additional Information
E-Series controller in lockdown state OE L7 due to sub-model identifier mismatch