E-Series controller locks down with status of "Memory Parity Error" and 7-segment code "OE L2 CF dx"
- Views:
- 1,869
- Visibility:
- Public
- Votes:
- 1
- Category:
- e-series-systems
- Specialty:
- esg
- Last Updated:
- 9/25/2023, 4:33:02 PM
Applies to
- All E-Series platforms.
- All E-Series software releases.
Issue
- Controller locks down with LED code of
OE L2 CF
dx (x: location of the cache DIMM). This code translates to persistent processor/cache DIMM ECC errors. - SANtricity System Manager or support bundle reports controller in Memory parity error status:
Status: Memory parity error
- Major event log and exception log if available (excLogShow) indicate the controller encountered correctable memory ECC errors before it failed.
Date/Time: **/**/**, 2:54:53 PM
Sequence number: ****
Event type: 2703
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Recoverable error in processor memory detected/corrected
Event specific codes: 0/0/0
Component type: Controller
Component location: Shelf **, Bay *
Logged by: Controller in bay *