Skip to main content
NetApp Knowledge Base

E-Series drives become missing or failed after upgrade to 11.70.1GA

Views:
335
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg
Last Updated:

Applies to

  • E-Series E3000, E28xx and E57xx platforms
  • Certain Toshiba drives. Model Numbers:
    • AL15SEB120N
    • AL15SEB18EQ
  • SANtricity OS 11.70.1GA

Issue

  • E-Series SANtricity System Manager reports either some drives as missing and/or system entering invalid configuration because the drives are inaccessible right after upgrading the SANtricity OS to 11.70.1GA.
  • E-Series SANtricity System Manager reports invalid drive format detected as seen below.

Invalid_Format_Error.png

  • Major event log reports event  "224d Drive failed - no response at start of day" indicating the drives are unresponsive. 

A:6/20/21, 11:29:32 PM (23:29:32) 2202 224d Drive failed - no response at start of day - Shelf 99, Bay 11 <--CRITICAL
A:6/20/21, 11:29:32 PM (23:29:32) 2201 224d Drive failed - no response at start of day - Shelf 99, Bay 10 <--CRITICAL
A:6/20/21, 11:29:32 PM (23:29:32) 2200 224d Drive failed - no response at start of day - Shelf 99, Bay 9 <--CRITICAL
A:6/20/21, 11:29:32 PM (23:29:32) 2199 224d Drive failed - no response at start of day - Shelf 99, Bay 8 <--CRITICAL
A:6/20/21, 11:29:32 PM (23:29:32) 2198 224d Drive failed - no response at start of day - Shelf 99, Bay 7 <--CRITICAL
A:6/20/21, 11:29:32 PM (23:29:32) 2197 224d Drive failed - no response at start of day - Shelf 99, Bay 6 <--CRITICAL
A:6/20/21, 11:29:32 PM (23:29:32) 2196 224d Drive failed - no response at start of day - Shelf 99, Bay 5 <--CRITICAL
A:6/20/21, 11:29:32 PM (23:29:32) 2195 224d Drive failed - no response at start of day - Shelf 99, Bay 4 <--CRITICAL
A:6/20/21, 11:29:32 PM (23:29:32) 2194 224d Drive failed - no response at start of day - Shelf 99, Bay 3 <--CRITICAL
A:6/20/21, 11:29:32 PM (23:29:32) 2193 224d Drive failed - no response at start of day - Shelf 99, Bay 2 <--CRITICAL
A:6/20/21, 11:29:32 PM (23:29:32) 2192 224d Drive failed - no response at start of day - Shelf 99, Bay 1 <--CRITICAL

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.