SRA 9.7+ configuration fails with "No storage replication adapters installed."
- Views:
- 2,222
- Visibility:
- Public
- Votes:
- 2
- Category:
- ontap-storage-replication-adapter
- Specialty:
- virt
- Last Updated:
Applies to
- Storage Replication Adapter (SRA) 9.x
- Site Recovery Manager (SRM) 8.x
- ONTAP Tools for VMware vSphere (OTV) 9.x
Issue
After uploading the SRA plugin to the SRM Appliance, the Storage Replication Adapters page in SRM reports the message No storage replication adapters installed.
Example:
The SRM vmware-dr logs may include messages like the following:
2020-04-22T16:37:43.647Z info vmware-dr[01047] [SRM@6876 sub=Storage opID=022a360e] Command queryCapabilities's stdout:
--> SRA Server IP file does not exist.vp_url =-1 Log_output : output = sra_server_url =-1
2020-04-22T16:37:43.647Z error vmware-dr[01047] [SRM@6876 sub=Storage opID=022a360e] Command queryCapabilities's stderr:
--> FATAL: sizeof(iv) should be equal to blocksize (16) at /usr/local/lib/perl5/site_perl/Crypt/Mode/CBC.pm line 20.