E-Series faulty drawer causes SAS_PORT_FAILED and Unknown status of StorageGRID node
- Views:
- 476
- Visibility:
- Public
- Votes:
- 0
- Category:
- storagegrid-webscale
- Specialty:
- sgrid
- Last Updated:
- 8/19/2025, 6:48:55 AM
Applies to
- E-Series
- StorageGRID Appliances SG5760 and SG6060
Issue
- SANtricity System Manger reporting the followings:
DISK_POOL_RECONSTRUCTION_DRIVE_COUNT_BELOW_THRESHOLD-Recovery Failure Type Code: 424
SAS_PORT_FAILED-Recovery Failure Type Code: 113
UNKNOWN_COMPONENT_STATUS-Recovery Failure Type Code: 61
Note: Multiple entries of this with location to a specific drawer
Example:Location: Controller/Drive Shelf 99 Drawer 5 A1
WB_CACHING_FORCIBLY_DISABLED-Recovery Failure Type Code: 378
VOLUME_GROUP_INCOMPLETE-Recovery Failure Type Code: 201
Note: Should haveShelf:
field matching the shelf of theUNKNOWN_COMPONENT_STATUS
location
Example:Shelf: Controller/Drive shelf 99, Drawer 5
SAS_PORT_FAILED-Recovery Failure Type Code: 113
- All disks in the affected drawer is missing
- Storage node reporting
Unknown
state in StorageGRID Grid Manager - Storage > POOLS & VOLUME GROUPS in SANtricity System Manger indicates the status of the disk pool as
Failed