StorageGRID appliance compute controller power supply has a problem
Applies to
- NetApp StorageGRID
- StorageGRID Appliances: SG1XX, SG1XXX and SG6XXX
Issue
- StorageGRID Grid Manager reports one of the below alerts for compute controller power supply:
Appliance compute controller power supply A has a problemCompute controller power supply A: Unknown
- The
bycast.login/var/local/log/shows the following failure messages for the Power Supply:
Nov 22 20:01:39 <node_name> ADE: |16701338 0082291168 RSMR UPDL 2022-11-22T20:01:39.684890| WARNING 0240 CCST: IPMI device PSU1_Status reports non-OK status 'Presence detected' 'Predictive Failure' 'Power Supply input lo
Nov 22 20:01:39 <node-name> ADE: |16701338 0082291168 RSMR UPDL 2022-11-22T20:01:39.684911| WARNING 0240 CCST: IPMI device PSU Redundancy reports non-OK status 'Redundancy Lost'
- The
status.jsonfile in gemini-system-status folder/var/local/gemini-system-statusin base OS or\var\local\gemini-system-statusin log bundle reports the following status:
"name": "PSU1_Status",
"type": "Power Supply",
"reading": "N/A",
"units": "N/A",
"event": "'Presence detected' 'Predictive Failure' 'Power Supply input lost"