E-Series ST8000NM018B drive failure with an assert storm
Applies to
- NetApp E-Series
- StorageGRID Appliances
- Drive model: ST8000NM018B
- Drive Firmware: NE01
Issue
- ST8000NM018B drive fails due to write failure. A
226c
drive failure event is logged by E-Series software.
B:9/4/23, 12:20:45 AM (00:20:45) 4890 226c Drive failure - Shelf 0, Drawer 5, Bay 9 - Cause: 3 = Write failure; Drive WWN: 5000c500f0XXXXXX; SN: WRQ1LKEQ00XXXXXXXXXX <--CRITICAL
- Immediately after the failure, a drive returned check condition event 100a is logged indicating the drive encountered an assertion storm (Sense Key / ASC / ASCQ:
2/4/f2
)
B:9/4/23, 12:20:48 AM (00:20:48) 4893 100a Drive returned CHECK CONDITION - Shelf 0, Drawer 5, Bay 9
----> Sense 2/4/f2 = Not Ready - Logical unit not ready, assert storm threshold being exceeded - CDB: 0x1b = Start/Stop Unit - LBA: 0x17f000040f8ca58