StorageGRID detects hardware fault for Volt_PxV_BAT due to faulty CMOS battery
Applies to
- NetApp StorageGRID
- Appliance Models: SGF60xx, SG60xx, SG100 and SG1000
Issue
- StorageGRID reports:
- Alert
Appliance compute controller needs attention - Alert
A hardware fault has been detected in the compute controller of a StorageGRID appliance - Alarm
CCNA (Compute Controller Needs Attention)
- Alert
- For StorageGRID 11.9 or later, the following alert is also detected
Appliance CMOS battery fault
A problem was detected with the CMOS battery in the appliance.
- BMC interface > Sensor,
Volt_PxV_BATreports:
90 Jan/6/2022 17:47:24 [Critical] [Volt_P3V_BAT] [Voltage]Lower Critical - Going Low (Reading: 2.289 Volts/ Threshold: 2.520 Volts) - Asserted
89 Jan/6/2022 17:46:55 [Information] [Volt_P3V_BAT] [Voltage]Lower Critical - Going Low (Reading: 2.667 Volts/ Threshold: 2.520 Volts) - Deasserted
bycast.logreports P3V non-OK error:
WARNING 0283 CCST: IPMI device Volt_P3V_BAT reports non-OK status 'At or Below (<=) Lower Critical Threshold'