StorageGRID detects hardware fault for Volt_PxV_BAT due to faulty CMOS battery
- Views:
- 2,021
- Visibility:
- Public
- Votes:
- 0
- Category:
- storagegrid
- Specialty:
- sgrid
- Last Updated:
- 6/16/2025, 12:24:22 PM
Applies to
- StorageGRID
- StorageGRID Appliances SGF60xx, SG600xx, SG100 and SG1000
Issue
- StorageGRID reports:
- Alert
Appliance compute controller needs attention
- Alarm
CCNA (Compute Controller Needs Attention)
- Alert
- For StorageGRID 11.9 or later, the following alert is detected
Appliance CMOS battery fault
A problem was detected with the CMOS battery in the appliance.
- BMC interface > Sensor,
Volt_PxV_BAT
reports:
90 Jan/6/2022 17:47:24 [Critical] [Volt_P3V_BAT] [Voltage]Lower Critical - Going Low (Reading: 2.289 Volts/ Threshold: 2.520 Volts) - Asserted
89 Jan/6/2022 17:46:55 [Information] [Volt_P3V_BAT] [Voltage]Lower Critical - Going Low (Reading: 2.667 Volts/ Threshold: 2.520 Volts) - Deasserted