Single Storage Node showing Storage appliance link down on network port alert
Applies to
- NetApp StorageGRID
- StorageGRID Appliances
Issue
StorageGRID reports storage appliance link down on network port <port> after a network related event.
- After the network connectivity is restored, the port shows Up from StorageGRID > Storage Node > Network:
Example:

- The
Storage appliance link down on network portalert is still reported, even if the network recovers.

- Running
cat /sys/class/net/hic*/carriervia SSH session, the status is0from the affected node:

- Running
ip addr showcommand, the affected port isDOWNfrom the affected node:
4: hic1: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc mq master bond1 state UP group default qlen 1000
link/ether d0:39:ea:13:a6:db brd ff:ff:ff:ff:ff:ff
5: hic2: <NO-CARRIER,BROADCAST,MULTICAST,SLAVE,UP> mtu 1500 qdisc mq master bond0 state DOWN group default qlen 1000
link/ether d0:39:ea:13:a6:dc brd ff:ff:ff:ff:ff:ff