Storage Replication Adapter: SRA configuration fails with "No storage replication adapters installed."
- Views:
- 2,990
- Visibility:
- Public
- Votes:
- 6
- Category:
- ontap-storage-replication-adapter
- Specialty:
- virt
- Last Updated:
Applies to
- Storage Replication Adapter (SRA) 9.x
- Site Recovery Manager (SRM) 8.x
- ONTAP Tools for VMware vSphere (OTV) 9.x
Issue
After uploading the SRA plugin to the SRM Appliance, the Storage Replication Adapters page in SRM reports:
No storage replication adapters installed.
Example:
The SRM vmware-dr logs may include messages like the following:
2020-04-22T16:37:43.647Z info vmware-dr[01047] [SRM@6876 sub=Storage opID=022a360e] Command queryCapabilities's stdout:
--> SRA Server IP file does not exist.vp_url =-1 Log_output : output = sra_server_url =-1
2020-04-22T16:37:43.647Z error vmware-dr[01047] [SRM@6876 sub=Storage opID=022a360e] Command queryCapabilities's stderr:
--> FATAL: sizeof(iv) should be equal to blocksize (16) at /usr/local/lib/perl5/site_perl/Crypt/Mode/CBC.pm line 20.